OPATŘIL, Lukáš, Roman PANOVSKÝ, Mary MOJICA-PISCIOTTI, Jan MÁCHAL, Jan KREJČÍ, Tomáš HOLEČEK, Lucia MASÁROVÁ, Věra FEITOVÁ, Július GODAVA, Vladimír KINCL, Tomáš KEPÁK, Gabriela ZÁVODNÁ a Lenka ŠPINAROVÁ. Stress pulmonary circulation parameters assessed by a cardiovascular magnetic resonance in patients after a heart transplant. Scientific Reports. Berlin: Nature, 2022, roč. 12, č. 1, s. 1-10. ISSN 2045-2322. Dostupné z: https://dx.doi.org/10.1038/s41598-022-09739-z.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Stress pulmonary circulation parameters assessed by a cardiovascular magnetic resonance in patients after a heart transplant
Autoři OPATŘIL, Lukáš (203 Česká republika, domácí), Roman PANOVSKÝ (203 Česká republika, garant, domácí), Mary MOJICA-PISCIOTTI, Jan MÁCHAL (203 Česká republika, domácí), Jan KREJČÍ (203 Česká republika, domácí), Tomáš HOLEČEK (203 Česká republika), Lucia MASÁROVÁ (703 Slovensko, domácí), Věra FEITOVÁ (203 Česká republika), Július GODAVA (703 Slovensko), Vladimír KINCL (203 Česká republika, domácí), Tomáš KEPÁK (203 Česká republika), Gabriela ZÁVODNÁ (203 Česká republika, domácí) a Lenka ŠPINAROVÁ (203 Česká republika, domácí).
Vydání Scientific Reports, Berlin, Nature, 2022, 2045-2322.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 30201 Cardiac and Cardiovascular systems
Stát vydavatele Německo
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 4.600
Kód RIV RIV/00216224:14110/22:00125708
Organizační jednotka Lékařská fakulta
Doi http://dx.doi.org/10.1038/s41598-022-09739-z
UT WoS 000782202600081
Klíčová slova anglicky Stress pulmonary circulation; cardiovascular magnetic resonance; heart transplant
Štítky 14110115, 14110518, rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Tereza Miškechová, učo 341652. Změněno: 19. 7. 2022 13:08.
Anotace
Rest pulmonary circulation parameters such as pulmonary transit time (PTT), heart rate corrected PTT (PTTc) and pulmonary transit beats (PTB) can be evaluated using several methods, including the first-pass perfusion from cardiovascular magnetic resonance. As previously published, up to 58% of patients after HTx have diastolic dysfunction detectable only in stress conditions. By using adenosine stress perfusion images, stress analogues of the mentioned parameters can be assessed. By dividing stress to rest biomarkers, potential new ratio parameters (PTT ratio and PTTc ratio) can be obtained. The objectives were to (1) provide more evidence about stress pulmonary circulation biomarkers, (2) present stress to rest ratio parameters, and (3) assess these biomarkers in patients with presumed diastolic dysfunction after heart transplant (HTx) and in childhood cancer survivors (CCS) without any signs of diastolic dysfunction. In this retrospective study, 48 patients after HTx, divided into subgroups based on echocardiographic signs of diastolic dysfunction (41 without, 7 with) and 39 CCS were enrolled. PTT was defined as the difference between the onset time of the signal intensity increase in the left and the right ventricle. PTT in rest conditions were without significant differences when comparing the CCS and HTx subgroup without diastolic dysfunction (4.96 ± 0.93 s vs. 5.51 ± 1.14 s, p = 0.063) or with diastolic dysfunction (4.96 ± 0.93 s vs. 6.04 ± 1.13 s, p = 0.13). However, in stress conditions, both PTT and PTTc were significantly lower in the CCS group than in the HTx subgroups, (PTT: 3.76 ± 0.78 s vs. 4.82 ± 1.03 s, p < 0.001; 5.52 ± 1.56 s, p = 0.002). PTT ratio and PTTc ratio were below 1 in all groups. In conclusion, stress pulmonary circulation parameters obtained from CMR showed prolonged PTT and PTTc in HTx groups compared to CCS, which corresponds with the presumption of underlying diastolic dysfunction. The ratio parameters were less than 1.
VytisknoutZobrazeno: 21. 7. 2024 02:19