DVOŘÁK, Pavel, Juraj PÁLENIK, Maroš TKÁČIK and Zdeněk POSPÍŠIL. Langmuir probe without RF compensation. Plasma Sources Science and Technology. IOP Publishing Ltd, 2022, vol. 31, No 8, p. 1-5. ISSN 0963-0252. Available from: https://dx.doi.org/10.1088/1361-6595/ac83eb.
Other formats:   BibTeX LaTeX RIS
Basic information
Original name Langmuir probe without RF compensation
Authors DVOŘÁK, Pavel (203 Czech Republic, guarantor, belonging to the institution), Juraj PÁLENIK (703 Slovakia, belonging to the institution), Maroš TKÁČIK (703 Slovakia, belonging to the institution) and Zdeněk POSPÍŠIL (203 Czech Republic, belonging to the institution).
Edition Plasma Sources Science and Technology, IOP Publishing Ltd, 2022, 0963-0252.
Other information
Original language English
Type of outcome Article in a journal
Field of Study 10305 Fluids and plasma physics
Country of publisher United Kingdom of Great Britain and Northern Ireland
Confidentiality degree is not subject to a state or trade secret
WWW URL
Impact factor Impact factor: 3.800
RIV identification code RIV/00216224:14310/22:00126312
Organization unit Faculty of Science
Doi http://dx.doi.org/10.1088/1361-6595/ac83eb
UT WoS 000841586300001
Keywords (in Czech) plazma; Langmuirova sonda; nekompenzovaná sonda; potenciál plazmatu; CCP
Keywords in English plasma; Langmuir probe; uncompensated probe; plasma potential; CCP
Tags rivok
Tags International impact, Reviewed
Changed by Changed by: Mgr. Marie Šípková, DiS., učo 437722. Changed: 22/2/2024 10:18.
Abstract
Langmuir probes with RF compensation are used for measurements of electron concentration, electron temperature and the DC value of plasma potential in RF discharges. In order to obtain all the RF components of plasma potential, simple probes without RF compensation are used. However, it has been believed that these uncompensated probes can not be used for determination of the DC value of plasma potential and of electron concentration and temperature, since their VA characteristics is distorted by the RF current. Consequently, the evaluation of data measured with uncompensated probes was not possible without additional measurement with a RF compensated Langmuir probe. This contribution analyzes the possibility to use uncompensated probes not only for measurement of RF components of plasma potential, but also for measurement of the DC component of plasma potential, electron concentration and electron temperature.
Links
GA19-15240S, research and development projectName: Multifunkční nanokompozitní polymerní tenké vrstvy s řízenými povrchovými a mechanickými vlastnostmi připravené v RF prachovém plazmatu
Investor: Czech Science Foundation
90097, large research infrastructuresName: CEPLANT
PrintDisplayed: 25/5/2024 15:19