Detailed Information on Publication Record
1998
Use of internal standardization to compensate for a wide range of absorbance in the analysis of glasses by UV-laser ablation inductively coupled plasma atomic emission spectrometry
KANICKÝ, Viktor, Vítězslav OTRUBA and Jean - Michel MERMETBasic information
Original name
Use of internal standardization to compensate for a wide range of absorbance in the analysis of glasses by UV-laser ablation inductively coupled plasma atomic emission spectrometry
Authors
KANICKÝ, Viktor (203 Czech Republic, guarantor), Vítězslav OTRUBA (203 Czech Republic) and Jean - Michel MERMET (250 France)
Edition
Applied Spectroscopy, USA, Society Appl. Spectroscopy, 1998, 0003-7028
Other information
Language
English
Type of outcome
Článek v odborném periodiku
Field of Study
10406 Analytical chemistry
Country of publisher
United States of America
Confidentiality degree
není předmětem státního či obchodního tajemství
Impact factor
Impact factor: 1.917
RIV identification code
RIV/00216224:14310/98:00000032
Organization unit
Faculty of Science
Keywords in English
Glass materials; Asorbance range; Atomic emission spectrometry; Inductively coupled plasma; Laser ablation; Internal standardization; Acoustic signal normalization
Tags
Tags
International impact, Reviewed
Změněno: 29/6/2007 09:57, prof. RNDr. Viktor Kanický, DrSc.
V originále
A frequency-tripled Q-switched Nd:YAG laser (355 nm, 10 Hz, 5 mJ per shot, Surelite, Continuum) was used for the ablation of glasses as direct solid sampling for inductively coupled plasma atomic emission spectrometric multichannel detection. The colored and transparent glasses were glass standards used for calibration in ii-ray fluorescence spectrometry and exhibited a 0.15-3.5 absorbance range at 355 nn. Translation of the target (1 mm s(-1)) with respect to the laser beam was used over a length of 16 mm. The depths and widths of the corresponding patterns were not related to the absorbance of the samples. However, the analytical Line intensities were efficiently compensated for by using the Si(I) 251.611 nm line as an internal standard. The repeatability was therefore improved for Na, K, Ca, Mg, Sr, Ba, Zn, Pb, Al, Fe, and Sb, as well as the correlation coefficients of the regression and the centroid uncertainties of the calibration graph. Preliminary investigations were carried out to evaluate the acoustic signal emitted by the microplasma as external standardization. However, a negative correlation was found with the Line intensity signals under our operating conditions.
In Czech
A frequency-tripled Q-switched Nd:YAG laser (355 nm, 10 Hz, 5 mJ per shot, Surelite, Continuum) was used for the ablation of glasses as direct solid sampling for inductively coupled plasma atomic emission spectrometric multichannel detection. The colored and transparent glasses were glass standards used for calibration in ii-ray fluorescence spectrometry and exhibited a 0.15-3.5 absorbance range at 355 nn. Translation of the target (1 mm s(-1)) with respect to the laser beam was used over a length of 16 mm. The depths and widths of the corresponding patterns were not related to the absorbance of the samples. However, the analytical Line intensities were efficiently compensated for by using the Si(I) 251.611 nm line as an internal standard. The repeatability was therefore improved for Na, K, Ca, Mg, Sr, Ba, Zn, Pb, Al, Fe, and Sb, as well as the correlation coefficients of the regression and the centroid uncertainties of the calibration graph. Preliminary investigations were carried out to evaluate the acoustic signal emitted by the microplasma as external standardization. However, a negative correlation was found with the Line intensity signals under our operating conditions.
Links
GA203/94/0511, research and development project |
|