J 2023

Small-bowel capsule endoscopy and device-assisted enteroscopy for diagnosis and treatment of small-bowel disorders: European Society of Gastrointestinal Endoscopy (ESGE) Guideline - Update 2022

PENNAZIO, Marco, Emanuele RONDONOTTI, Edward J DESPOTT, Xavier DRAY, Martin KEUCHEL et. al.

Základní údaje

Originální název

Small-bowel capsule endoscopy and device-assisted enteroscopy for diagnosis and treatment of small-bowel disorders: European Society of Gastrointestinal Endoscopy (ESGE) Guideline - Update 2022

Autoři

PENNAZIO, Marco, Emanuele RONDONOTTI, Edward J DESPOTT, Xavier DRAY, Martin KEUCHEL, Tom MOREELS, David S SANDERS, Cristiano SPADA, Cristina CARRETERO, Pablo Cortegoso VALDIVIA, Luca ELLI, Lorenzo FUCCIO, Begona Gonzalez SUAREZ, Anastasios KOULAOUZIDIS, Lumír KUNOVSKÝ (203 Česká republika, domácí), Deirdre MCNAMARA, Helmut NEUMANN, Enrique PEREZ-CUADRADO-MARTINEZ, Enrique PEREZ-CUADRADO-ROBLES, Stefania PICCIRELLI, Bruno ROSA, Jean Christophe SAURIN, Reena SIDHU, Ilja TACHECI, Erasmia VLACHOU a Konstantinos TRIANTAFYLLOU

Vydání

Endoscopy, STUTTGART, GEORG THIEME VERLAG KG, 2023, 0013-726X

Další údaje

Jazyk

angličtina

Typ výsledku

Článek v odborném periodiku

Obor

30219 Gastroenterology and hepatology

Stát vydavatele

Německo

Utajení

není předmětem státního či obchodního tajemství

Odkazy

Impakt faktor

Impact factor: 9.300 v roce 2022

Kód RIV

RIV/00216224:14110/23:00130087

Organizační jednotka

Lékařská fakulta

UT WoS

000892335200004

Klíčová slova anglicky

small-bowel capsule endoscopy; device-assisted enteroscopy; small-bowel disorders

Štítky

Příznaky

Mezinárodní význam, Recenzováno
Změněno: 26. 1. 2024 10:21, Mgr. Tereza Miškechová

Anotace

V originále

Main RecommendationsMR1 ESGE recommends small-bowel capsule endoscopy as the first-line examination, before consideration of other endoscopic and radiological diagnostic tests for suspected small-bowel bleeding, given the excellent safety profile of capsule endoscopy, its patient tolerability, and its potential to visualize the entire small-bowel mucosa.Strong recommendation, moderate quality evidence.MR2 ESGE recommends small-bowel capsule endoscopy in patients with overt suspected small-bowel bleeding as soon as possible after the bleeding episode, ideally within 48 hours, to maximize the diagnostic and subsequent therapeutic yield.Strong recommendation, high quality evidence.MR3 ESGE does not recommend routine second-look endoscopy prior to small-bowel capsule endoscopy in patients with suspected small-bowel bleeding or iron-deficiency anemia.Strong recommendation, low quality evidence.MR4 ESGE recommends conservative management in those patients with suspected small-bowel bleeding and high quality negative small-bowel capsule endoscopy.Strong recommendation, moderate quality evidence.MR5 ESGE recommends device-assisted enteroscopy to confirm and possibly treat lesions identified by small-bowel capsule endoscopy.Strong recommendation, high quality evidence.MR6 ESGE recommends the performance of small-bowel capsule endoscopy as a first-line examination in patients with iron-deficiency anemia when small bowel evaluation is indicated.Strong recommendation, high quality evidence.MR7 ESGE recommends small-bowel capsule endoscopy in patients with suspected Crohn's disease and negative ileocolonoscopy findings as the initial diagnostic modality for investigating the small bowel, in the absence of obstructive symptoms or known bowel stenosis.Strong recommendation, high quality evidence.MR8 ESGE recommends, in patients with unremarkable or nondiagnostic findings from dedicated small-bowel cross-sectional imaging, small-bowel capsule endoscopy as a subsequent investigation if deemed likely to influence patient management.Strong recommendation, low quality evidence.MR9 ESGE recommends, in patients with established Crohn's disease, the use of a patency capsule before small-bowel capsule endoscopy to decrease the capsule retention rate.Strong recommendation, moderate quality evidence.MR10 ESGE recommends device-assisted enteroscopy (DAE) as an alternative to surgery for foreign bodies retained in the small bowel requiring retrieval in patients without acute intestinal obstruction.Strong recommendation, moderate quality evidence.MR11 ESGE recommends DAE-endoscopic retrograde cholangiopancreatography (DAE-ERCP) as a first-line endoscopic approach to treat pancreaticobiliary diseases in patients with surgically altered anatomy (except for Billroth II patients).Strong recommendation, moderate quality evidence.