2022
Use of free radial forearm and pronator quadratus muscle flap: Anatomical study and clinical application
KEMPNÝ, Tomáš, Zuzana MUSILOVÁ, Martin KNOZ, Marek JOUKAL, Břetislav LIPOVÝ et. al.Základní údaje
Originální název
Use of free radial forearm and pronator quadratus muscle flap: Anatomical study and clinical application
Autoři
KEMPNÝ, Tomáš (203 Česká republika), Zuzana MUSILOVÁ (203 Česká republika, domácí), Martin KNOZ (203 Česká republika, domácí), Marek JOUKAL (203 Česká republika, garant, domácí), Břetislav LIPOVÝ (203 Česká republika, domácí), Jakub HOLOUBEK (203 Česká republika, domácí), Wolfgang Paul PÖSCHL (40 Rakousko) a Hsu-Tang CHENG
Vydání
JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, OXFORD, ELSEVIER SCI LTD, 2022, 1748-6815
Další údaje
Jazyk
angličtina
Typ výsledku
Článek v odborném periodiku
Obor
30212 Surgery
Stát vydavatele
Česká republika
Utajení
není předmětem státního či obchodního tajemství
Odkazy
Impakt faktor
Impact factor: 2.700
Kód RIV
RIV/00216224:14110/22:00128199
Organizační jednotka
Lékařská fakulta
UT WoS
000907046600007
Klíčová slova anglicky
Radial forearm flap (RFF); Pronator quadratus muscle (PQM); Anatomical study; Radial artery
Příznaky
Mezinárodní význam, Recenzováno
Změněno: 9. 1. 2024 10:20, Mgr. Tereza Miškechová
Anotace
V originále
The authors present an anatomical study and clinical experience with radial fore-arm flap (RFF) and pronator quadratus muscle (PQM) application in the reconstruction of various body areas. The aim was to describe the anatomical placement and proportions of the PQM, the anatomical location of the major arterial branch of the radial artery supplying the PQM, and the application of this knowledge in clinical practice.The anatomical study was based upon an analysis of 13 fresh adult cadaver upper extremities, of which nine were female and four male; both arms from the same donors were used in four cases. The study of the PQM was performed using a dye-containing intraarterial injection, stan-dard macro- and micro-preparation techniques, and chemical digestion. The data on the PQM size in males and females, thickness of the radial artery branch (the principal artery nourishing the muscle), and its position were analysed. The radial artery branch nourishing the PQM was identified in all cadaveric specimens of the anatomical study. In addition, 12 patients underwent reconstructions of soft and bony tissue defects using a RFF + PQM (pedicled or free flap). The radial artery branch perfusing the PQM was identi-fied in all cases. The flap was used for the management of defects of the head (seven cases), arm (three cases) and lower leg (two cases). The harvest site healed well in all cases and, with the exception of one case in which a partial necrosis of the flap was observed, all flaps remained viable, which demonstrated the safety of the method.
Návaznosti
MUNI/A/1331/2021, interní kód MU |
|