HAVELKOVÁ, Alena, Petr DVORAK, Jarmila SIEGELOVÁ, Petr DOBŠÁK, Petr FILIPENSKY a Germaine CORNELISSEN. Possibilities of Interpreting the Night-to-Day Ratio Specified by 24-Hour Blood Pressure Monitoring. International Journal of Clinical Practice. LONDON: WILEY-HINDAWI, 2023, roč. 2023, February 2023, s. 1-11. ISSN 1368-5031. Dostupné z: https://dx.doi.org/10.1155/2023/6530295.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Possibilities of Interpreting the Night-to-Day Ratio Specified by 24-Hour Blood Pressure Monitoring
Autoři HAVELKOVÁ, Alena (203 Česká republika, garant, domácí), Petr DVORAK (203 Česká republika), Jarmila SIEGELOVÁ (203 Česká republika, domácí), Petr DOBŠÁK (203 Česká republika, domácí), Petr FILIPENSKY (203 Česká republika) a Germaine CORNELISSEN (840 Spojené státy).
Vydání International Journal of Clinical Practice, LONDON, WILEY-HINDAWI, 2023, 1368-5031.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 30218 General and internal medicine
Stát vydavatele Velká Británie a Severní Irsko
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 2.600 v roce 2022
Kód RIV RIV/00216224:14110/23:00130346
Organizační jednotka Lékařská fakulta
Doi http://dx.doi.org/10.1155/2023/6530295
UT WoS 000935553300002
Klíčová slova anglicky Blood Pressure Monitoring; Night-to-Day Ratio
Štítky 14110614, rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Tereza Miškechová, učo 341652. Změněno: 26. 7. 2023 10:52.
Anotace
Aim. Specify the risk rate of incorrect patient classification based on the night-to-day ratio specification from singular 24-h ABPM in comparison to the results of 7-day ABPM monitoring Materials and Methods. 1197 24 h cycles were enrolled in 171 subjects in the study and divided into 4 groups: group 1 (40 healthy men and women without exercise), group 2 (40 healthy exercise-training men and women), group 3 (40 patients with ischemic coronary artery disease without exercise), and group 4 (51 patients with ischemic coronary artery disease following cardiovascular rehabilitation). The subject of the evaluation was the percentage rate of incorrect subject classification (dipper, nondipper, extreme dipper, and riser) based on the mean blood pressure values for 7 days and from seven independent 24-hour cycles (the mean value mode). Results. In the case of the individuals included in the monitored groups, the mean night-to-day ratio-based (mode for the 7 days versus the individual days of 24-hour monitoring) classification accordance ranged between 59% and 62%. Only in singular cases did the accordance reach 0% or 100%. The accordance size was not dependent on the health or cardiovascular disease (; 56% vs. 54%) or physical activity (; 55% vs. 54%) of the monitored individuals. Conclusion. The specification of the night-to-day ratio of each individual for each day of the 7-day ABPM monitoring would be the most convenient option. In many patients, diagnosing could thus be based on the most frequently occurring values (mode specification). The study protocol was registered with ClinicalTrials.gov (NCT05264090).
Návaznosti
LM2023049, projekt VaVNázev: Český národní uzel Evropské sítě infrastruktur klinického výzkumu
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, CZECRIN - Czech National Node to the European Clinical Research Infrastructure Network
VytisknoutZobrazeno: 22. 7. 2024 02:29