ZEMAN, Jiří, David VETCHÝ, Sylvie PAVLOKOVÁ, Aleš FRANC a Vladimír PITSCHMANN. Eudragit® RL coated pellets with immobilized butyrylcholinesterase for rapid detection of cholinesterase inhibitors in water. In 4th European Conference on Pharmaceutics. 2023.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Eudragit® RL coated pellets with immobilized butyrylcholinesterase for rapid detection of cholinesterase inhibitors in water
Autoři ZEMAN, Jiří (203 Česká republika, garant, domácí), David VETCHÝ (203 Česká republika, domácí), Sylvie PAVLOKOVÁ (203 Česká republika, domácí), Aleš FRANC (203 Česká republika, domácí) a Vladimír PITSCHMANN (203 Česká republika).
Vydání 4th European Conference on Pharmaceutics, 2023.
Další údaje
Originální jazyk angličtina
Typ výsledku Konferenční abstrakt
Obor 30104 Pharmacology and pharmacy
Stát vydavatele Česká republika
Utajení není předmětem státního či obchodního tajemství
WWW Webová stránka konference
Kód RIV RIV/00216224:14160/23:00134605
Organizační jednotka Farmaceutická fakulta
Klíčová slova anglicky detection tube; nerve agent; Neusilin; cholinesterase; color transition; stability
Štítky ÚFT
Příznaky Mezinárodní význam
Změnil Změnil: PharmDr. Jiří Zeman, Ph.D., učo 387771. Změněno: 14. 3. 2024 11:01.
Anotace
Nerve agents (soman, sarin, tabun, VX), organophosphate (parathion, malathion) and carbamate (aldicarb) pesticides are commonly referred to as cholinesterase inhibitors (ChI), which are substances with very high toxicity. A fast, cheap, and sensitive sensor is needed to detect ChI as quickly as possible in order to carry out the appropriate treatment for those affected. Detection tubes (DTs) that use pellets with immobilized cholinesterase for colorimetric detection of the ChI presence, are just the type of detector that meets the above-mentioned requirements. Moreover, enzyme-based biosensors such as DTs have a detection limit between 0.005–0.01 mg∙m−3, which is the lowest in comparison with more expensive and unportable detectors using GC-MS, FTIR or IMS. DTs are based on fast enzymatic Ellman reaction. However, it suffers from an indistinct color transition from white to yellow in the absence of ChI. In this study, an innovative carrier in the form of coated matrix pellets was prepared utilizing the advantages of the previous experiment. The pellet cores contained the unique sorbent – Neusilin® US2 and the semipermeable coating consisted mainly of Eudragit® RL. The main aim of the experiment was to evaluate reaction rate, sensitivity, and color transition intensity of prepared samples in comparison with previous types of carriers.
Návaznosti
VI20192022172, projekt VaVNázev: Detekční trubičky druhé generace pro kontinuální a opakované monitorování nervově paralytických a jiných toxických látek
Investor: Ministerstvo vnitra ČR, Detekční trubičky druhé generace pro kontinuální a opakované monitorování nervově paralytických a jiných toxických látek
VytisknoutZobrazeno: 23. 7. 2024 21:23