Safety and performance of a novel implantable sensor in the inferior vena cava under acute and chronic intravascular volume modulation

SHERIDAN, Stephen William, Friedrich WETTERLING, Jeffrey Moore TESTANI, Barry A A BORLAUG, Marat FUDIM et. al.

Základní údaje

Originální název

Safety and performance of a novel implantable sensor in the inferior vena cava under acute and chronic intravascular volume modulation

Autoři

SHERIDAN, Stephen William, Friedrich WETTERLING (garant), Jeffrey Moore TESTANI, Barry A A BORLAUG, Marat FUDIM, Kevin DAMMAN, Alastair GRAY, Peter GAINES, Martin POLOCZEK (203 Česká republika, domácí), Stephen MADDEN, Tucker JAMES, Teresa BUXO, Robert GAUL, Louise CORCORAN, Fiachra SWEENEY a Daniel BURKHOFF

Vydání

European Journal of heart Failure, Hoboken, Wiley, 2023, 1388-9842

Další údaje

Jazyk

angličtina

Typ výsledku

Článek v odborném periodiku

Obor

30201 Cardiac and Cardiovascular systems

Stát vydavatele

Spojené státy

Utajení

není předmětem státního či obchodního tajemství

Odkazy

Impakt faktor

Impact factor: 18.200 v roce 2022

Kód RIV

RIV/00216224:14110/23:00131029

Organizační jednotka

Lékařská fakulta

UT WoS

000946155400001

Klíčová slova anglicky

Heart failure; Inferior vena cava; Right atrial pressure; Models; Animal; Chronic and acute response; Intravascular congestion

Štítky

Příznaky

Mezinárodní význam, Recenzováno
Změněno: 5. 4. 2024 08:29, Mgr. Tereza Miškechová

Anotace

V originále

Aims The management of congestion is one of the key treatment targets in heart failure. Assessing congestion is, however, difficult. The purpose of this study was to investigate the safety and dynamic response of a novel, passive, inferior vena cava (IVC) sensor in a chronic ovine model.Methods and results A total of 20 sheep divided into three groups were studied in acute and chronic in vivo settings. Group I and Group II included 14 sheep in total with 12 sheep receiving the sensor and two sheep receiving a control device (IVC filter). Group III included an additional six animals for studying responses to volume challenges via infusion of blood and saline solutions. Deployment was 100% successful with all devices implanted; performing as expected with no device-related complications and signals were received at all observations. At similar volume states no significant differences in IVC area normalized to absolute area range were measured (55 +/- 17% on day 0 and 62 +/- 12% on day 120, p = 0.51). Chronically, the sensors were completely integrated with a thin, reendothelialized neointima with no loss of sensitivity to infused volume. Normalized IVC area changed significantly from 25 +/- 17% to 43 +/- 11% (p =0.007) with 300 ml infused. In contrast, right atrial pressure required 1200 ml of infused volume prior to a statistically significant change from 3.1 +/- 2.6 mmHg to 7.5 +/- 2.0 mmHg (p = 0.02).Conclusion In conclusion, IVC area can be measured remotely in real-time using a safe, accurate, wireless, and chronic implantable sensor promising to detect congestion with higher sensitivity than filling pressures.