FALT, Premysl a Lumír KUNOVSKÝ. Recurrent bleeding in a patient with hepaticojejunostomy caused by Dieulafoy's lesion. UNITED EUROPEAN GASTROENTEROLOGY JOURNAL. ENGLAND: JOHN WILEY & SONS LTD, 2023, roč. 11, č. 9, s. 904-905. ISSN 2050-6406. Dostupné z: https://dx.doi.org/10.1002/ueg2.12440.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Recurrent bleeding in a patient with hepaticojejunostomy caused by Dieulafoy's lesion
Autoři FALT, Premysl (203 Česká republika) a Lumír KUNOVSKÝ (203 Česká republika, garant, domácí).
Vydání UNITED EUROPEAN GASTROENTEROLOGY JOURNAL, ENGLAND, JOHN WILEY & SONS LTD, 2023, 2050-6406.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 30219 Gastroenterology and hepatology
Stát vydavatele Velká Británie a Severní Irsko
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 6.000 v roce 2022
Kód RIV RIV/00216224:14110/23:00131596
Organizační jednotka Lékařská fakulta
Doi http://dx.doi.org/10.1002/ueg2.12440
UT WoS 001034053400001
Klíčová slova anglicky bleeding; Dieulafoy's lesion; endoscopy; enteroscopy; hepaticojejunostomy
Štítky 14110223, rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Tereza Miškechová, učo 341652. Změněno: 2. 2. 2024 12:43.
Anotace
A 27-year-old woman was referred to our endoscopy center for recurrent upper gastrointestinal bleeding requiring multiple blood transfusions over 4 years. She had undergone common bile duct resection with hepaticojejunostomy and cholecystectomy due to choledochal cyst at age 4. Repeated upper endoscopy, colonoscopy, CT angiography, video capsule endoscopy (VCE), magnetic resonance cholangiopancreatography, and scintigraphy were negative. Cap-assisted motorized spiral enteroscopy was performed and Y-Roux-en afferent loop with hepaticojejunostomy was reached (Figure 1). Just below the anastomotic line was a diminutive ulceration with prominent pulsating vessel (Figure 2). When touched by the cap, the ulceration immediately began to spurt blood (Figure 3). Treatment was by argon plasma coagulation (APC), endoclips, and inserting a double pig-tail 7 French stent (Figure 4). The biliary plastic stent was placed to avoid a possible stenosis in the anastomosis after the use of APC and application of endoclips near the anastomosis. At 3 month follow-up of enteroscopy, the stent was removed. The patient is being followed up and has shown no signs of ongoing bleeding.
VytisknoutZobrazeno: 30. 8. 2024 11:14