VAŠÍČKOVÁ, Zuzana, Petr KLIMES, Jan CIMBÁLNÍK, Vojtech TRAVNICEK, Martin PAIL, Josef HALAMEK, Pavel JURAK a Milan BRÁZDIL. Shadows of very high-frequency oscillations can be detected in lower frequency bands of routine stereoelectroencephalography. Nature Scientific Reports. Berlin: NATURE, 2023, roč. 13, č. 1, s. 1-8. ISSN 2045-2322. Dostupné z: https://dx.doi.org/10.1038/s41598-023-27797-9.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Shadows of very high-frequency oscillations can be detected in lower frequency bands of routine stereoelectroencephalography
Autoři VAŠÍČKOVÁ, Zuzana (703 Slovensko, domácí), Petr KLIMES (203 Česká republika, garant), Jan CIMBÁLNÍK (203 Česká republika), Vojtech TRAVNICEK (203 Česká republika), Martin PAIL (203 Česká republika, domácí), Josef HALAMEK (203 Česká republika), Pavel JURAK (203 Česká republika) a Milan BRÁZDIL (203 Česká republika, domácí).
Vydání Nature Scientific Reports, Berlin, NATURE, 2023, 2045-2322.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 30210 Clinical neurology
Stát vydavatele Německo
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 4.600 v roce 2022
Kód RIV RIV/00216224:14110/23:00134288
Organizační jednotka Lékařská fakulta
Doi http://dx.doi.org/10.1038/s41598-023-27797-9
UT WoS 000988257400048
Klíčová slova anglicky stereoelectroencephalography
Štítky 14110127, podil, rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Tereza Miškechová, učo 341652. Změněno: 15. 11. 2023 14:22.
Anotace
Very high-frequency oscillations (VHFOs, > 500 Hz) are more specific in localizing the epileptogenic zone (EZ) than high-frequency oscillations (HFOs, < 500 Hz). Unfortunately, VHFOs are not visible in standard clinical stereo-EEG (SEEG) recordings with sampling rates of 1 kHz or lower. Here we show that "shadows" of VHFOs can be found in frequencies below 500 Hz and can help us to identify SEEG channels with a higher probability of increased VHFO rates. Subsequent analysis of Logistic regression models on 141 SEEG channels from thirteen patients shows that VHFO "shadows" provide additional information to gold standard HFO analysis and can potentially help in precise EZ delineation in standard clinical recordings.
Návaznosti
GA22-28784S, projekt VaVNázev: Vysokofrekvenční epileptiformní aktivita v lidském mozku na makro- a mikroskopické úrovni
Investor: Grantová agentura ČR, Vysokofrekvenční epileptiformní aktivita v lidském mozku na makro- a mikroskopické úrovni
VytisknoutZobrazeno: 20. 8. 2024 23:22