KOSMÁKOVÁ, Anna, Zuzana ZAJICKOVA a Jiří URBAN. Characterization of hybrid organo-silica monoliths for possible application in the gradient elution of peptides. Journal of Separation Science. Weinheim: Wiley, 2023, roč. 46, č. 24, s. 1-10. ISSN 1615-9306. Dostupné z: https://dx.doi.org/10.1002/jssc.202300617.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Characterization of hybrid organo-silica monoliths for possible application in the gradient elution of peptides
Autoři KOSMÁKOVÁ, Anna (203 Česká republika, domácí), Zuzana ZAJICKOVA a Jiří URBAN (203 Česká republika, garant, domácí).
Vydání Journal of Separation Science, Weinheim, Wiley, 2023, 1615-9306.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10406 Analytical chemistry
Stát vydavatele Německo
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 3.100 v roce 2022
Kód RIV RIV/00216224:14310/23:00132318
Organizační jednotka Přírodovědecká fakulta
Doi http://dx.doi.org/10.1002/jssc.202300617
UT WoS 001090480500001
Klíčová slova anglicky gradient elution; hybrid organo-silica monoliths; kinetic analysis; peptides
Štítky rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Pavla Foltynová, Ph.D., učo 106624. Změněno: 18. 1. 2024 13:07.
Anotace
We characterized thermally polymerized organo-silica hybrid monolithic capillaries to test their applicability in the gradient elution of peptides. We have used a single-pot approach utilizing 3-(methacryloyloxy)propyltrimethoxysilane (MPTMS), ethylene dimethacrylate (EDMA), and n-octadecyl methacrylate (ODM) as functional monomers. The organo-silica monolith containing MPTMS and EDMA was compared with the stationary phase prepared by adding ODM to the original polymerization mixture. Column prepared using a three-monomer system provided a lower accessible volume of flow-through pores, a higher proportion of mesopores, and higher efficiency. We utilized isocratic and gradient elution data to predict peak widths in gradient elution. Both protocols provided comparable results and can be used for peptide peak width prediction. However, applying gradient elution data for peak width prediction seems simpler. Finally, we tested the effect of gradient time on achievable peak capacity in the gradient elution of peptides with a column prepared with a three-monomer system providing a higher peak capacity. However, the performance of hybrid organo-silica monolithic stationary phases in gradient elution of peptides must be improved compared to other monolithic stationary phases. The limiting factor is column efficiency in highly aqueous mobile phases, which needs to be focused on.
Návaznosti
GA23-07581S, projekt VaVNázev: Vícerozměrná proteomická analýza proteinů a peptidů
Investor: Grantová agentura ČR, Vícerozměrná proteomická analýza proteinů a peptidů
VytisknoutZobrazeno: 12. 7. 2024 13:01