2023
Benchmarking of Two Peptide Clean-Up Protocols: SP2 and Ethyl Acetate Extraction for Sodium Dodecyl Sulfate or Polyethylene Glycol Removal from Plant Samples before LC-MS/MS
MARTINKOVÁ, Petra, Hana KONEČNÁ, Petr GINTAR, Karolína KRYŠTOFOVÁ, David POTĚŠIL et. al.Základní údaje
Originální název
Benchmarking of Two Peptide Clean-Up Protocols: SP2 and Ethyl Acetate Extraction for Sodium Dodecyl Sulfate or Polyethylene Glycol Removal from Plant Samples before LC-MS/MS
Autoři
MARTINKOVÁ, Petra (203 Česká republika, domácí), Hana KONEČNÁ (203 Česká republika, domácí), Petr GINTAR (203 Česká republika, domácí), Karolína KRYŠTOFOVÁ (203 Česká republika, domácí), David POTĚŠIL (203 Česká republika, domácí), Martin TRTÍLEK (203 Česká republika) a Zbyněk ZDRÁHAL (203 Česká republika, garant, domácí)
Vydání
INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, MDPI, 2023, 1661-6596
Další údaje
Jazyk
angličtina
Typ výsledku
Článek v odborném periodiku
Obor
10608 Biochemistry and molecular biology
Stát vydavatele
Švýcarsko
Utajení
není předmětem státního či obchodního tajemství
Odkazy
Impakt faktor
Impact factor: 5.600 v roce 2022
Kód RIV
RIV/00216224:14740/23:00133126
Organizační jednotka
Středoevropský technologický institut
UT WoS
001132258900001
Klíčová slova anglicky
peptide clean-up; magnetic beads; SP2; ethyl acetate extraction; sodium dodecyl sulfate; detergent; polyethylene glycol; Arabidopsis thaliana; LC-MS/MS
Příznaky
Mezinárodní význam, Recenzováno
Změněno: 2. 11. 2024 20:14, Ing. Martina Blahová
Anotace
V originále
The success of bottom-up proteomic analysis frequently depends on the efficient removal of contaminants from protein or peptide samples before LC-MS/MS. For a peptide clean-up workflow, single-pot solid-phase-enhanced peptide sample preparation on carboxylate-modified paramagnetic beads (termed SP2) was evaluated for sodium dodecyl sulfate or polyethylene glycol removal from Arabidopsis thaliana tryptic peptides. The robust and efficient 40-min SP2 protocol, tested for 10-ng, 250-ng, and 10-µg peptide samples, was proposed and benchmarked thoroughly against the ethyl acetate extraction protocol. The SP2 protocol on carboxylated magnetic beads proved to be the most robust approach, even for the simultaneous removal of massive sodium dodecyl sulfate (SDS) and polyethylene glycol (PEG) contaminations from AT peptide samples in respect of the LC-MS/MS data outperforming ethyl acetate extraction.
Návaznosti
EF16_026/0008446, projekt VaV |
| ||
EF18_072/0015659, projekt VaV |
| ||
LM2023042, projekt VaV |
| ||
90254, velká výzkumná infrastruktura |
|