TARABEK, Peter, Branislav VRANA, Katarina CHALUPKOVA, Alena BEDNARIKOVA, Linda OKSOVA, Peter BYSTRICKY, Nataliia LEONOVA a Olga KONOVALOVA. Examining the applicability of polar organic chemical integrative sampler for long-term monitoring of groundwater contamination caused by currently used pesticides. Science of the Total Environment. AMSTERDAM: Elsevier, 2023, roč. 903, December 2023, s. 1-14. ISSN 0048-9697. Dostupné z: https://dx.doi.org/10.1016/j.scitotenv.2023.165905.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Examining the applicability of polar organic chemical integrative sampler for long-term monitoring of groundwater contamination caused by currently used pesticides
Autoři TARABEK, Peter, Branislav VRANA (703 Slovensko, garant, domácí), Katarina CHALUPKOVA, Alena BEDNARIKOVA, Linda OKSOVA, Peter BYSTRICKY, Nataliia LEONOVA a Olga KONOVALOVA.
Vydání Science of the Total Environment, AMSTERDAM, Elsevier, 2023, 0048-9697.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10511 Environmental sciences
Stát vydavatele Nizozemské království
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 9.800 v roce 2022
Kód RIV RIV/00216224:14310/23:00133133
Organizační jednotka Přírodovědecká fakulta
Doi http://dx.doi.org/10.1016/j.scitotenv.2023.165905
UT WoS 001109436000001
Klíčová slova anglicky Water quality monitoring; Passive sampling; POCIS; Sampling rate; Water framework directive
Štítky rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Michaela Hylsová, Ph.D., učo 211937. Změněno: 8. 3. 2024 21:22.
Anotace
The possibilities of expanding a groundwater quality monitoring scheme by passive sampling using polar organic chemical integrative sampler (POCIS) comprising HLB sorbent as the receiving phase were explored. Passive sampling and grab sampling were carried out simultaneously in the regions with vulnerable groundwater resources in Slovakia, between 2013 and 2021. For 27 pesticides and degradation products detected both in POCIS and the grab samples, in situ sampling rates were calculated and statistically evaluated. The limited effectiveness of the receiving phase in POCIS for sampling polar or ionized compounds was confirmed through a comparison of the medians of compound-specific sampling rates. For the majority of the monitored compounds the median sampling rates varied between 0.01 and 0.035 L/day. In some cases, the actual in situ values could be confirmed by parallel exposure of POCIS and silicone rubber sheet employed to obtain a benchmark for maximum attainable sampling rate. Sampling site and sampling period appear to have also some influence on the sampling rates, which was attributed in part to the groundwater velocity varying in both space and time. The influence of physico-chemical parameters (temperature, pH, electrolytic conductivity) remains mostly questionable due to the naturally limited ranges of recorded values over the entire duration of the study. Concentrations of pollutants in POCIS could be used for predicting time weighed average concentrations in water, provided the sampling rates were known and relatively constant. Generally, the compound-specific sampling rate cannot be considered constant due to a combination of naturally varying environmental factors that influence the actual in situ sampling rate. The relative standard deviation of concentration data from POCIS exposed in triplicates varied between approx. 5 %-50 %. Utilizing exploratory data analysis approach and tools enabled us to obtain a relatively complex picture of the situation and progress regarding pesticide pollution of groundwater in the monitored areas.
Návaznosti
EF17_043/0009632, projekt VaVNázev: CETOCOEN Excellence
GX20-04676X, projekt VaVNázev: Holistická charakterizace expozice a potenciálních účinků komplexních směsí chemických látek ve vodním prostředí
Investor: Grantová agentura ČR, Holistická charakterizace expozice a potenciálních účinků komplexních směsí chemických látek ve vodním prostředí
857560, interní kód MU
(Kód CEP: EF17_043/0009632)
Název: CETOCOEN Excellence (Akronym: CETOCOEN Excellence)
Investor: Evropská unie, CETOCOEN Excellence, Spreading excellence and widening participation
90269, velká výzkumná infrastrukturaNázev: RECETOX RI II
VytisknoutZobrazeno: 24. 7. 2024 13:29