NEVELIKOVA, Marketa, Filip DOSBABA, Garyfallia PEPERA, Marián FELŠŐCI, Katerina BATALIKOVA, Jing Jing SU a Ladislav BAŤALÍK. Validity and reliability of automated treadmill six-minute walk test in patients entering exercise-based cardiac rehabilitation. Annals of Medicine. ABINGDON: TAYLOR & FRANCIS LTD, 2023, roč. 55, č. 2, s. 1-9. ISSN 0785-3890. Dostupné z: https://dx.doi.org/10.1080/07853890.2024.2304664.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Validity and reliability of automated treadmill six-minute walk test in patients entering exercise-based cardiac rehabilitation
Autoři NEVELIKOVA, Marketa (203 Česká republika), Filip DOSBABA (203 Česká republika, domácí), Garyfallia PEPERA (300 Řecko), Marián FELŠŐCI (703 Slovensko), Katerina BATALIKOVA (203 Česká republika), Jing Jing SU (156 Čína) a Ladislav BAŤALÍK (203 Česká republika, garant, domácí).
Vydání Annals of Medicine, ABINGDON, TAYLOR & FRANCIS LTD, 2023, 0785-3890.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 30217 Urology and nephrology
Stát vydavatele Velká Británie a Severní Irsko
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 4.400 v roce 2022
Kód RIV RIV/00216224:14110/23:00133342
Organizační jednotka Lékařská fakulta
Doi http://dx.doi.org/10.1080/07853890.2024.2304664
UT WoS 001144285600001
Klíčová slova anglicky Six minute walk test; cardiac rehabilitation; automatized treadmill; functional capacity; technology-assisted assessment
Štítky 14110614, rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Tereza Miškechová, učo 341652. Změněno: 31. 1. 2024 10:29.
Anotace
Introduction: The six-minute walk test (6MWT) is a well-established tool for assessing submaximal functional capacity for cardiac patients, but space limitations challenge its implementation. Treadmill-based (TR) 6MWT is a promising alternative, but it requires patients to complete a familiarization test to adapt treadmill speed regulation. With the advancement of sensors, it is possible to automatically control speed for individual patients and thus overcome the space limitation or the speed control difficulty on the treadmill for each patient.Methods: This study investigated the validity and interchangeability of automated speed TR6MWT and standard hallway (HL) 6MWT. Eighteen patients were assessed at baseline of the 12-week cardiac rehabilitation program. Fourteen of them were assessed after rehabilitation. All patients performed three TR6MWTs and three HL6MWTs at baseline and one of each test after the program.Results: Patients well tolerated the TR6MWT. There was a strong correlation between both test methods (r = 0.79). However, patients performed significantly better in HL6MWT (514.8m +/- 59.7m) than in TR6MWT (447.2 +/- 79.1m) with 95% CI, 40.4-94.6m, p < 0.05. Both tests showed high test-retest reliability (intraclass correlation coefficient of 0.86). The TR6MWT showed a valuable comparison of the effect of the cardiac rehabilitation program (20% increase, effect size 1.1) even though it is not interchangeable with the HL6MWT.Conclusion: The automated speed TR6MWT appears to be an acceptable tool with adequate validity, reliability, and responsiveness for assessing functional capacity in patients utilizing cardiac rehabilitation programs.
VytisknoutZobrazeno: 4. 8. 2024 12:16