J 2024

Emergency medicine pharmacotherapy compromises accuracy of plasma creatinine determination by enzyme-based methods: real-world clinical evidence and implications for clinical practice

DEMLOVÁ, Regina, Šárka KOZÁKOVÁ, Michal ŘIHÁČEK, Dana BUČKOVÁ, Kateřina HORSKÁ et. al.

Základní údaje

Originální název

Emergency medicine pharmacotherapy compromises accuracy of plasma creatinine determination by enzyme-based methods: real-world clinical evidence and implications for clinical practice

Autoři

DEMLOVÁ, Regina (203 Česká republika, domácí), Šárka KOZÁKOVÁ (203 Česká republika, domácí), Michal ŘIHÁČEK (203 Česká republika, domácí), Dana BUČKOVÁ (203 Česká republika, domácí), Kateřina HORSKÁ (203 Česká republika, domácí), Ondřej WIEWIORKA (203 Česká republika, domácí), Luboš BOUČEK (203 Česká republika), Iveta SELINGEROVÁ (203 Česká republika, domácí), Martina PODBORSKÁ (203 Česká republika, domácí), Alena KORBEROVÁ (203 Česká republika), Alena MIKUŠKOVÁ (203 Česká republika, domácí), Jiří ŠTARHA (203 Česká republika, domácí), Miroslava BEŇOVSKÁ (203 Česká republika, domácí), Martin RADINA (203 Česká republika), Michal RICHTER (203 Česká republika), Lenka ZDRAŽILOVÁ DUBSKÁ (203 Česká republika, domácí) a Dalibor VALÍK (203 Česká republika, domácí)

Vydání

Frontiers in Medicine, Laussane, Frontiers, 2024, 2296-858X

Další údaje

Jazyk

angličtina

Typ výsledku

Článek v odborném periodiku

Obor

30104 Pharmacology and pharmacy

Stát vydavatele

Švýcarsko

Utajení

není předmětem státního či obchodního tajemství

Odkazy

Impakt faktor

Impact factor: 3.900 v roce 2022

Organizační jednotka

Lékařská fakulta

UT WoS

001154759700001

Klíčová slova anglicky

creatinine; renal functions; eGFR; urgent care medication; cystatin C

Příznaky

Mezinárodní význam, Recenzováno
Změněno: 16. 8. 2024 07:32, Mgr. Tereza Miškechová

Anotace

V originále

Background: Assessment of kidney function in emergency settings is essential across all medical subspecialties. Daily assessment of patient creatinine results from emergency medical services showed that some deviated from expected values, implying drug-related interference. Methods: Real-time clinical evaluation of an enzyme method (Roche CREP2) in comparison with the Jaffe gen. 2 method (Roche CREJ2) was performed. During the period of December 2022 and January 2023, we analyzed 8,498 patient samples, where 5,524 were heavily medicated STAT patient specimens, 500 were pediatric specimens, and 2,474 were from a distant general population in a different region using the same methods. Results: In 109 out of 5,524 hospital specimens (1.97%, p < 0.001), the CREP2 value was apparently (25% or more) lower than CREJ2. Suspect interfering medication was found in a sample of 43 out of 46 reviewed patients where medication data were available. This phenomenon was not observed in the general population. Conclusion: In a polymedicated urgent care hospital population, a creatinine enzyme method produces unreliable results, apparently due to multiple drug-related interferences.

Návaznosti

CZ.02.1.01/0.0/0.0/16_013/0001826, interní kód MU
(Kód CEP: EF16_013/0001826)
Název: CZECRIN_PRO PACIENTY - zavádění inovativních moderních terapií
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, CZECRIN_PRO PACIENTY - zavádění inovativních moderních terapií, PO 1 Posilování kapacit pro kvalitní výzkum
101059788, interní kód MU
Název: Central European Advanced Therapy and Immunotherapy Centre
Investor: Evropská unie, Central European Advanced Therapy and Immunotherapy Centre, Rozšiřování účasti a posílení ERA
90249, velká výzkumná infrastruktura
Název: CZECRIN IV