Další formáty:
BibTeX
LaTeX
RIS
@article{2377086, author = {Demlová, Regina and Kozáková, Šárka and Řiháček, Michal and Bučková, Dana and Horská, Kateřina and Wiewiorka, Ondřej and Bouček, Luboš and Selingerová, Iveta and Podborská, Martina and Korberová, Alena and Mikušková, Alena and Štarha, Jiří and Beňovská, Miroslava and Radina, Martin and Richter, Michal and Zdražilová Dubská, Lenka and Valík, Dalibor}, article_location = {Laussane}, article_number = {January 2024}, doi = {http://dx.doi.org/10.3389/fmed.2023.1236948}, keywords = {creatinine; renal functions; eGFR; urgent care medication; cystatin C}, language = {eng}, issn = {2296-858X}, journal = {Frontiers in Medicine}, title = {Emergency medicine pharmacotherapy compromises accuracy of plasma creatinine determination by enzyme-based methods: real-world clinical evidence and implications for clinical practice}, url = {https://www.frontiersin.org/journals/medicine/articles/10.3389/fmed.2023.1236948/full}, volume = {10}, year = {2024} }
TY - JOUR ID - 2377086 AU - Demlová, Regina - Kozáková, Šárka - Řiháček, Michal - Bučková, Dana - Horská, Kateřina - Wiewiorka, Ondřej - Bouček, Luboš - Selingerová, Iveta - Podborská, Martina - Korberová, Alena - Mikušková, Alena - Štarha, Jiří - Beňovská, Miroslava - Radina, Martin - Richter, Michal - Zdražilová Dubská, Lenka - Valík, Dalibor PY - 2024 TI - Emergency medicine pharmacotherapy compromises accuracy of plasma creatinine determination by enzyme-based methods: real-world clinical evidence and implications for clinical practice JF - Frontiers in Medicine VL - 10 IS - January 2024 SP - 1-16 EP - 1-16 PB - Frontiers SN - 2296858X KW - creatinine KW - renal functions KW - eGFR KW - urgent care medication KW - cystatin C UR - https://www.frontiersin.org/journals/medicine/articles/10.3389/fmed.2023.1236948/full N2 - Background: Assessment of kidney function in emergency settings is essential across all medical subspecialties. Daily assessment of patient creatinine results from emergency medical services showed that some deviated from expected values, implying drug-related interference. Methods: Real-time clinical evaluation of an enzyme method (Roche CREP2) in comparison with the Jaffe gen. 2 method (Roche CREJ2) was performed. During the period of December 2022 and January 2023, we analyzed 8,498 patient samples, where 5,524 were heavily medicated STAT patient specimens, 500 were pediatric specimens, and 2,474 were from a distant general population in a different region using the same methods. Results: In 109 out of 5,524 hospital specimens (1.97%, p < 0.001), the CREP2 value was apparently (25% or more) lower than CREJ2. Suspect interfering medication was found in a sample of 43 out of 46 reviewed patients where medication data were available. This phenomenon was not observed in the general population. Conclusion: In a polymedicated urgent care hospital population, a creatinine enzyme method produces unreliable results, apparently due to multiple drug-related interferences. ER -
DEMLOVÁ, Regina, Šárka KOZÁKOVÁ, Michal ŘIHÁČEK, Dana BUČKOVÁ, Kateřina HORSKÁ, Ondřej WIEWIORKA, Luboš BOUČEK, Iveta SELINGEROVÁ, Martina PODBORSKÁ, Alena KORBEROVÁ, Alena MIKUŠKOVÁ, Jiří ŠTARHA, Miroslava BEŇOVSKÁ, Martin RADINA, Michal RICHTER, Lenka ZDRAŽILOVÁ DUBSKÁ a Dalibor VALÍK. Emergency medicine pharmacotherapy compromises accuracy of plasma creatinine determination by enzyme-based methods: real-world clinical evidence and implications for clinical practice. \textit{Frontiers in Medicine}. Laussane: Frontiers, 2024, roč.~10, January 2024, s.~1-16. ISSN~2296-858X. Dostupné z: https://dx.doi.org/10.3389/fmed.2023.1236948.
|