KOLAR, Radim, Tomas VICAR, Jiri CHMELIK, Roman JAKUBICEK, Jan ODSTRCILIK, Eva VALTEROVA, Michal NOHEL, Karolína SKORKOVSKÁ a Ralf P TORNOW. Assessment of retinal vein pulsation through video-ophthalmoscopy and simultaneous biosignals acquisition. Biomedical Optics Express. WASHINGTON: OPTICA PUBLISHING GROUP, 2023, roč. 14, č. 6, s. 2645-2657. ISSN 2156-7085. Dostupné z: https://dx.doi.org/10.1364/BOE.486052.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Assessment of retinal vein pulsation through video-ophthalmoscopy and simultaneous biosignals acquisition
Autoři KOLAR, Radim (203 Česká republika), Tomas VICAR (203 Česká republika), Jiri CHMELIK (203 Česká republika), Roman JAKUBICEK (203 Česká republika), Jan ODSTRCILIK (203 Česká republika), Eva VALTEROVA (203 Česká republika), Michal NOHEL (203 Česká republika), Karolína SKORKOVSKÁ (203 Česká republika, domácí) a Ralf P TORNOW.
Vydání Biomedical Optics Express, WASHINGTON, OPTICA PUBLISHING GROUP, 2023, 2156-7085.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 30207 Ophthalmology
Stát vydavatele Spojené státy
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 3.400 v roce 2022
Kód RIV RIV/00216224:14110/23:00133679
Organizační jednotka Lékařská fakulta
Doi http://dx.doi.org/10.1364/BOE.486052
UT WoS 001019493200001
Klíčová slova anglicky retinal vein pulsation; ophthalmoscopy; simultaneous biosignals acquisition
Štítky 14110615, rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Tereza Miškechová, učo 341652. Změněno: 29. 2. 2024 08:06.
Anotace
The phenomenon of retinal vein pulsation is still not a deeply understood topic in retinal hemodynamics. In this paper, we present a novel hardware solution for recording retinal video sequences and physiological signals using synchronized acquisition, we apply the photoplethysmographic principle for the semi-automatic processing of retinal video sequences and we analyse the timing of the vein collapse within the cardiac cycle using of an electrocardiographic signal (ECG). We measured the left eyes of healthy subjects and determined the phases of vein collapse within the cardiac cycle using a principle of photoplethysmography and a semi-automatic image processing approach. We found that the time to vein collapse (Tvc) is between 60 ms and 220 ms after the R-wave of the ECG signal, which corresponds to 6% to 28% of the cardiac cycle. We found no correlation between Tvc and the duration of the cardiac cycle and only a weak correlation between Tvc and age (0.37, p = 0.20), and Tvc and systolic blood pressure (-0.33, p = 0.25). The Tvc values are comparable to those of previously published papers and can contribute to the studies that analyze vein pulsations.
VytisknoutZobrazeno: 3. 7. 2024 02:31