KOŠŤÁL, Michal, Zdeněk MATĚJ, Martin SCHULC, Evžen LOSA, Jan ŠIMON, Evžen NOVÁK, František CVACHOVEC, Václav PŘENOSIL, Filip MRAVEC, Tomáš CZAKOJ, Vojtěch RYPAR, Andrej TRKOV a Roberto CAPOTE. Benchmarking of stainless steel cube neutron leakage in Research Center Rez. NUCLEAR SCIENCE AND ENGINEERING. UNITED STATES: TAYLOR & FRANCIS INC, 2024, roč. 2024, č. 198, s. 399-410. ISSN 0029-5639. Dostupné z: https://dx.doi.org/10.1080/00295639.2023.2206770.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Benchmarking of stainless steel cube neutron leakage in Research Center Rez
Autoři KOŠŤÁL, Michal (203 Česká republika, garant), Zdeněk MATĚJ (203 Česká republika, domácí), Martin SCHULC, Evžen LOSA, Jan ŠIMON, Evžen NOVÁK, František CVACHOVEC (203 Česká republika), Václav PŘENOSIL (203 Česká republika), Filip MRAVEC, Tomáš CZAKOJ, Vojtěch RYPAR, Andrej TRKOV a Roberto CAPOTE.
Vydání NUCLEAR SCIENCE AND ENGINEERING, UNITED STATES, TAYLOR & FRANCIS INC, 2024, 0029-5639.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 20201 Electrical and electronic engineering
Stát vydavatele Spojené státy
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 1.200 v roce 2022
Organizační jednotka Fakulta informatiky
Doi http://dx.doi.org/10.1080/00295639.2023.2206770
UT WoS 001017662700001
Klíčová slova anglicky Neutron spectrometryneutron transport in steelactivation detectors in steelMCNP6
Změnil Změnil: doc. RNDr. Zdeněk Matěj, Ph.D., učo 72963. Změněno: 26. 3. 2024 12:20.
Anotace
Integral experiments covering neutron leakage from geometrically simple assemblies with a Cf-252 source inside are very valuable tools usable in the validation of transport cross-section data since geometric uncertainties play a much smaller role in simple geometric assemblies than in complex assemblies as for example reactor pressure vessel geometry. Since Cf-252 spontaneous fission is a standard neutron source, the uncertainties connected with the source neutron spectrum can be even neglected. The paper refers to validation efforts of neutron leakage from an similar to 50 x 50 x 50-cm stainless steel block in the Research Center Rez. Both the neutron leakage flux at a distance of 1 m from the center of the cubical assembly using stilbene spectrometry and activation rates at different positions of the assembly were evaluated. In addition to experiments, main sources of uncertainty were identified and evaluated. The results of the stilbene measurements are consistent with the activation measurement results.
VytisknoutZobrazeno: 19. 7. 2024 12:19