APOSTOLOPOULOS, Vasileios, Petr BOHÁČ, Petr MARCIÁN, Luboš NACHTNEBL, Michal MAHDAL, Lukáš PAZOUREK a Tomáš TOMÁŠ. Biomechanical comparison of all-polyethylene total knee replacement and its metal-backed equivalent on periprosthetic tibia using the finite element method. JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH. LONDON: BMC, 2024, roč. 19, č. 1, s. 1-12. ISSN 1749-799X. Dostupné z: https://dx.doi.org/10.1186/s13018-024-04631-0.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Biomechanical comparison of all-polyethylene total knee replacement and its metal-backed equivalent on periprosthetic tibia using the finite element method
Název anglicky Biomechanical comparison of all-polyethylene total knee replacement and its metal-backed equivalent on periprosthetic tibia using the finite element method
Autoři APOSTOLOPOULOS, Vasileios (203 Česká republika, garant, domácí), Petr BOHÁČ (203 Česká republika), Petr MARCIÁN (203 Česká republika), Luboš NACHTNEBL (203 Česká republika, domácí), Michal MAHDAL (203 Česká republika, domácí), Lukáš PAZOUREK (203 Česká republika, domácí) a Tomáš TOMÁŠ (203 Česká republika, domácí).
Vydání JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, LONDON, BMC, 2024, 1749-799X.
Další údaje
Originální jazyk čeština
Typ výsledku Článek v odborném periodiku
Obor 30211 Orthopaedics
Stát vydavatele Německo
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 2.600 v roce 2022
Organizační jednotka Lékařská fakulta
Doi http://dx.doi.org/10.1186/s13018-024-04631-0
UT WoS 001168403100001
Klíčová slova anglicky Total knee arthroplasty; Computational modeling; Finite element method; All-polyethylene tibial component; Metal-backed tibial component; TKR; Knee replacement; FEA
Štítky 14110123, rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Tereza Miškechová, učo 341652. Změněno: 3. 5. 2024 13:34.
Anotace
BackgroundTotal knee arthroplasty (TKA) with all-polyethylene tibial (APT) components has shown comparable survivorship and clinical outcomes to that with metal-backed tibial (MBT). Although MBT is more frequently implanted, APT equivalents are considered a low-cost variant for elderly patients. A biomechanical analysis was assumed to be suitable to compare the response of the periprosthetic tibia after implantation of TKA NexGen APT and MBT equivalent.MethodsA standardised load model was used representing the highest load achieved during level walking. The geometry and material models were created using computed tomography data. In the analysis, a material model was created that represents a patient with osteopenia.ResultsThe equivalent strain distribution in the models of cancellous bone with an APT component showed values above 1000 mu epsilon in the area below the medial tibial section, with MBT component were primarily localised in the stem tip area. For APT variants, the microstrain values in more than 80% of the volume were in the range from 300 to 1500 mu epsilon, MBT only in less than 64% of the volume.ConclusionThe effect of APT implantation on the periprosthetic tibia was shown as equal or even superior to that of MBT despite maximum strain values occurring in different locations. On the basis of the strain distribution, the state of the bone tissue was analysed to determine whether bone tissue remodelling or remodelling would occur. Following clinical validation, outcomes could eventually modify the implant selection criteria and lead to more frequent implantation of APT components.
Anotace anglicky
BackgroundTotal knee arthroplasty (TKA) with all-polyethylene tibial (APT) components has shown comparable survivorship and clinical outcomes to that with metal-backed tibial (MBT). Although MBT is more frequently implanted, APT equivalents are considered a low-cost variant for elderly patients. A biomechanical analysis was assumed to be suitable to compare the response of the periprosthetic tibia after implantation of TKA NexGen APT and MBT equivalent.MethodsA standardised load model was used representing the highest load achieved during level walking. The geometry and material models were created using computed tomography data. In the analysis, a material model was created that represents a patient with osteopenia.ResultsThe equivalent strain distribution in the models of cancellous bone with an APT component showed values above 1000 mu epsilon in the area below the medial tibial section, with MBT component were primarily localised in the stem tip area. For APT variants, the microstrain values in more than 80% of the volume were in the range from 300 to 1500 mu epsilon, MBT only in less than 64% of the volume.ConclusionThe effect of APT implantation on the periprosthetic tibia was shown as equal or even superior to that of MBT despite maximum strain values occurring in different locations. On the basis of the strain distribution, the state of the bone tissue was analysed to determine whether bone tissue remodelling or remodelling would occur. Following clinical validation, outcomes could eventually modify the implant selection criteria and lead to more frequent implantation of APT components.
VytisknoutZobrazeno: 13. 7. 2024 10:00