2024
Harmonized quality assurance/quality control provisions to assess completeness and robustness of MS1 data preprocessing for LC-HRMS-based suspect screening and non-targeted analysis
LENNON, Sarah, Jade CHAKER, Elliott James PRICE, Juliane HOLLENDER, Carolin HUBER et. al.Základní údaje
Originální název
Harmonized quality assurance/quality control provisions to assess completeness and robustness of MS1 data preprocessing for LC-HRMS-based suspect screening and non-targeted analysis
Autoři
LENNON, Sarah, Jade CHAKER, Elliott James PRICE (826 Velká Británie a Severní Irsko, garant, domácí), Juliane HOLLENDER, Carolin HUBER, Tobias SCHULZE, Lutz AHRENS, Frederic BEEN, Nicolas CREUSOT, Laurent DEBRAUWER, Gaud DERVILLY, Catherine GABRIEL, Thierry GUERIN, Baninia HABCHI, Emilien L. JAMIN, Jana KLÁNOVÁ (203 Česká republika, domácí), Tina KOSJEK, Bruno LE BIZEC, Jeroen MEIJER, Hans MOL, Rosalie NIJSSEN, Herbert OBERACHER, Nafsika PAPAIOANNOU, Julien PARINET, Dimosthenis SARIGIANNIS, Michael A. STRAVS, Žiga TKALEC (705 Slovinsko, domácí), Emma L. SCHYMANSKI, Marja LAMOREE, Jean-Philippe ANTIGNAC a Arthur DAVID
Vydání
TrAC Trends in Analytical Chemistry, Oxford, Elsevier, 2024, 0165-9936
Další údaje
Jazyk
angličtina
Typ výsledku
Článek v odborném periodiku
Obor
10406 Analytical chemistry
Stát vydavatele
Velká Británie a Severní Irsko
Utajení
není předmětem státního či obchodního tajemství
Odkazy
Impakt faktor
Impact factor: 13.100 v roce 2022
Organizační jednotka
Přírodovědecká fakulta
UT WoS
001223574100001
Klíčová slova anglicky
High-resolution mass spectrometry; Exposomics; Metabolomics; Non-targeted analysis; Suspect screening analysis; Data preprocessing; Contaminants of emerging concern; Chemical exposome; Harmonized QA/QC
Štítky
Příznaky
Mezinárodní význam, Recenzováno
Změněno: 5. 6. 2024 10:41, Mgr. Michaela Hylsová, Ph.D.
Anotace
V originále
Non-targeted and suspect screening analysis using liquid chromatography coupled to high-resolution mass spectrometry (LC-HRMS) holds great promise to comprehensively characterize complex chemical mixtures. Data preprocessing is a crucial part of the process, however, some limitations are observed: (i) peak-picking and feature extraction might be incomplete, especially for low abundant compounds, and (ii) limited reproducibility has been observed between laboratories and software for detected features and their relative quantification. We first conducted a critical review of existing solutions that could improve the reproducibility of preprocessing for LC-HRMS. Solutions include providing repositories and reporting guidelines, open and modular processing workflows, public benchmark datasets, tools to optimize the data preprocessing and to filter out false positive detections. We then propose harmonized quality assurance/quality control guidelines that would allow to assess the sensitivity of feature detection, reproducibility, integration accuracy, precision, accuracy, and consistency of data preprocessing for human biomonitoring, food and environmental communities.
Návaznosti
EF17_043/0009632, projekt VaV |
| ||
LM2023069, projekt VaV |
| ||
101057014, interní kód MU |
| ||
857560, interní kód MU (Kód CEP: EF17_043/0009632) |
|