KRÁL, Martin, Olga ŠVECOVÁ, Štefan ZELENÁK, Jiří PACHERNÍK, Tomáš BÁRTA, Jana ZÍDKOVÁ, Iva SYNKOVÁ, Samuel LIETAVA, Tomáš NOVOTNÝ a Markéta BÉBAROVÁ. Effect of isoprenaline and arrhythmogenic conditions on the spontaneous electrical activity of hiPSC-CM with Y4734C-RYR2 variant. In 48th Meeting of the European Working Group on Cardiac Cellular Electrophysiology. 2024.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Effect of isoprenaline and arrhythmogenic conditions on the spontaneous electrical activity of hiPSC-CM with Y4734C-RYR2 variant
Autoři KRÁL, Martin, Olga ŠVECOVÁ, Štefan ZELENÁK, Jiří PACHERNÍK, Tomáš BÁRTA, Jana ZÍDKOVÁ, Iva SYNKOVÁ, Samuel LIETAVA, Tomáš NOVOTNÝ a Markéta BÉBAROVÁ.
Vydání 48th Meeting of the European Working Group on Cardiac Cellular Electrophysiology, 2024.
Další údaje
Originální jazyk angličtina
Typ výsledku Konferenční abstrakt
Stát vydavatele Rakousko
Utajení není předmětem státního či obchodního tajemství
Organizační jednotka Lékařská fakulta
Klíčová slova anglicky RYR2, Y4734C, multielectrode array, electrical activity, isoprenaline
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: doc. MUDr. Markéta Bébarová, Ph.D., učo 15000. Změněno: 8. 7. 2024 12:25.
Anotace
Background: In a proband with idiopathic ventricular fibrillation (IF) and in his sister suffering from catecholaminergic polymorphic ventricular tachycardia (CPVT), p.Y4734C-RYR2 variant was found. Here we bring data showing the spontaneous electrical activity of cardiomyocytes derived from human-induced pluripotent stem cells (hiPSC-CM) of the proband (IF), his sister (CPVT), and his healthy nephew as control (WT), and its changes under arrhythmogenic conditions. Methods: The recordings by the multielectrode array technique were performed in control, i.e. in Tyrode solution with 5 mM K+ (5K++37°C), in 0.5 µM isoprenaline (ISO), and under cumulatively added hypokalemia (3K+), β-adrenergic stimulation (ISO), and hyperthermia (40°C). Considering non-normal data distribution, the cycle length (CL) and its short-term variability (STVCL) are shown as the median from n samples and non-parametric tests were used. Results: In 5K+, CPVT hiPSC-CM had a significantly longer CL (1.47 s, n=19; P˂0.05) than IF (1.05 s, n=32) and WT (0.77 s, n=7). ISO significantly shortened CL in all groups (by 38.3, 22.7, and 17.7 % in CPVT, IF, and WT, respectively, n=19, 32, and 7; P ˂ 0.05) and CPVT showed a significantly larger reaction than IF (P˂0.05). The arrhythmogenic factors caused a significant increment in STVCL in IF (41.91 in 3K+, 22.65 in 3K++ISO, and 65.38 ms in 3K++ISO+40°C, vs. 10.23 ms in control; n=24; P˂0.05) whereas it was significantly increased only in 3K+ in CPVT (21.14, 15.99, and 10.44 ms, respectively, vs. 13.13 in control; n=20; P˂0.05). IF and CPVT significantly differed in STVCL in 3K++ISO+40°C. Conclusions: CPVT hiPSC-CM showed a lower frequency of spontaneous activity and its higher reactivity to ISO. An increment in beat-to-beat variability of CL was observed during arrhythmogenic conditions in IF hiPSC-CM.
Návaznosti
MUNI/A/1547/2023, interní kód MUNázev: Analýza (dys)funkce: od molekul k živému organismu
Investor: Masarykova univerzita, Analýza (dys)funkce: od molekul k živému organismu
NU22-02-00348, projekt VaVNázev: Funkční hodnocení genetických variant u případů klinicky „skutečné“ idiopatické fibrilace komor: in vitro a in silico modelování s cílem odhalit arytmogenní mechanismus
Investor: Ministerstvo zdravotnictví ČR, Funkční hodnocení genetických variant u případů klinicky „skutečné“ idiopatické fibrilace komor: in vitro a in silico modelování s cílem odhalit arytmogenní mechanismus, Podprogram 1 - standardní
VytisknoutZobrazeno: 22. 7. 2024 23:33