JURKA, Martin, Iva MACOVA, Monika WAGNEROVA, Otakar CAPOUN, Roman JAKUBICEK, Petr OUŘEDNÍČEK, Lukas LAMBERT a Andrea BURGETOVA. Deep-learning-based reconstruction of T2-weighted magnetic resonance imaging of the prostate accelerated by compressed sensing provides improved image quality at half the acquisition time. QUANTITATIVE IMAGING IN MEDICINE AND SURGERY. SHATIN: AME PUBL CO, 2024, roč. 14, č. 5, s. 3534-3544. ISSN 2223-4292. Dostupné z: https://dx.doi.org/10.21037/qims-23-1488.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Deep-learning-based reconstruction of T2-weighted magnetic resonance imaging of the prostate accelerated by compressed sensing provides improved image quality at half the acquisition time
Autoři JURKA, Martin (203 Česká republika), Iva MACOVA (203 Česká republika), Monika WAGNEROVA (203 Česká republika), Otakar CAPOUN (203 Česká republika), Roman JAKUBICEK (203 Česká republika), Petr OUŘEDNÍČEK (203 Česká republika, domácí), Lukas LAMBERT (203 Česká republika) a Andrea BURGETOVA (203 Česká republika).
Vydání QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, SHATIN, AME PUBL CO, 2024, 2223-4292.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 30224 Radiology, nuclear medicine and medical imaging
Stát vydavatele Hongkong
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 2.800 v roce 2022
Organizační jednotka Lékařská fakulta
Doi http://dx.doi.org/10.21037/qims-23-1488
UT WoS 001250132200023
Klíčová slova anglicky Magnetic resonance imaging (MRI); prostate cancer; artificial intelligence (AI); image reconstruction
Štítky 14110119, rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Tereza Miškechová, učo 341652. Změněno: 9. 7. 2024 08:47.
Anotace
Background: Deep-learning-based reconstruction (DLR) improves the quality of magnetic resonance (MR) images which allows faster acquisitions. The aim of this study was to compare the image quality of standard and accelerated T2 weighted turbo-spin-echo (TSE) images of the prostate reconstructed with and without DLR and to find associations between perceived image quality and calculated image characteristics. Methods: In a cohort of 47 prospectively enrolled consecutive patients referred for bi-parametric prostate magnetic resonance imaging (MRI), two T2-TSE acquisitions in the transverse plane were acquired on a 3T scanner-a standard T2-TSE sequence and a short sequence accelerated by a factor of two using compressed sensing (CS). The images were reconstructed with and without DLR in super-resolution mode. The image quality was rated in six domains. Signal-to-noise ratio (SNR), and image sharpness were measured. Results: The mean acquisition time was 281 +/- 23 s for the standard and 140 +/- 12 s for the short acquisition (P<0.0001). DLR images had higher sharpness compared to non-DLR (P<0.001). Short and short-DLR had lower SNR than the standard and standard-DLR (P<0.001). The perceived image quality of short-DLR was rated better in all categories compared to the standard sequence (P<0.001 to P=0.004). All domains of subjective evaluation were correlated with measured image sharpness (P<0.001). Conclusions: T2-TSE acquisition of the prostate accelerated using CS combined with DLR reconstruction provides images with increased sharpness that have a superior quality as perceived by human readers compared to standard T2-TSE. The perceived image quality is correlated with measured image contrast.
VytisknoutZobrazeno: 10. 7. 2024 11:29