ODEHNALOVA, Klara, Petra PRIBILOVA, Blahoslav MARŠÁLEK a Pavel BABICA. A fast and reliable LC-MS-MS method for the quantification of saxitoxin in blood plasma samples. JOURNAL OF ANALYTICAL TOXICOLOGY. UNITED STATES: OXFORD UNIV PRESS INC, 2024, roč. 48, č. 2, s. 119-125. ISSN 0146-4760. Dostupné z: https://dx.doi.org/10.1093/jat/bkad092.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název A fast and reliable LC-MS-MS method for the quantification of saxitoxin in blood plasma samples
Autoři ODEHNALOVA, Klara, Petra PRIBILOVA, Blahoslav MARŠÁLEK (203 Česká republika, domácí) a Pavel BABICA (203 Česká republika, garant, domácí).
Vydání JOURNAL OF ANALYTICAL TOXICOLOGY, UNITED STATES, OXFORD UNIV PRESS INC, 2024, 0146-4760.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 30108 Toxicology
Stát vydavatele Spojené státy
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 2.500 v roce 2022
Organizační jednotka Přírodovědecká fakulta
Doi http://dx.doi.org/10.1093/jat/bkad092
UT WoS 001146868300001
Klíčová slova anglicky PARALYTIC SHELL; FISH TOXINS; SOLID-PHASE EXTRACTION; HUMAN URINE; NEOSAXITOXIN; ACCUMULATION; CYANOBACTERIAL; IDENTIFICATION; SERUM
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Michaela Hylsová, Ph.D., učo 211937. Změněno: 4. 8. 2024 20:32.
Anotace
Saxitoxins (STXs) are potent neurotoxins produced by marine dinoflagellates or freshwater cyanobacteria, known to cause acute and eventually fatal human intoxications, which are classified as paralytic shellfish poisonings (PSPs). Rapid analysis of STXs in blood plasma can be used for a timely diagnosis and confirmation of PSPs. We developed a fast and simple method of STX extraction based on plasma sample acidification and precipitation by acetonitrile, followed by quantification using liquid chromatography-tandem mass spectrometry (LC-MS-MS). Our approach provides the results <= 30 min, with a limit of detection of 2.8 ng/mL and a lower limit of quantification of 5.0 ng/mL. Within-run and between-run precision experiments showed good reproducibility with <= 15% values. Standard curves for calibration were linear with correlation coefficients >= 0.98 across the assay calibration range (5-200 ng/mL). In an interlaboratory analytical exercise, the method was found to be 100% accurate in determining the presence or absence of STX in human plasma specimens, with recovery values of 86-99%. This simple method for STX determination in animal or human plasma can quickly and reliably diagnose STX exposures and confirm suspected PSP cases to facilitate patient treatment or expedite necessary public health or security actions.
Návaznosti
EF17_043/0009632, projekt VaVNázev: CETOCOEN Excellence
LM2023069, projekt VaVNázev: Výzkumná infrastruktura RECETOX
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, Výzkumná infrastruktura RECETOX
VytisknoutZobrazeno: 6. 10. 2024 13:15