Lack of Prognostic Value of T-Wave Alternans for Implantable Cardioverter-Defibrillator Benefit in Primary Prevention

PELLI, Ari, Tuomas V KENTTA, M Juhani JUNTTILA, Cynthia HUBER, Simon SCHLOGL et. al.

Základní údaje

Originální název

Lack of Prognostic Value of T-Wave Alternans for Implantable Cardioverter-Defibrillator Benefit in Primary Prevention

Autoři

PELLI, Ari, Tuomas V KENTTA, M Juhani JUNTTILA, Cynthia HUBER, Simon SCHLOGL, Markus ZABEL, Marek MALÍK (203 Česká republika, domácí), Rik WILLEMS, Marc A VOS, Markus HARDEN, Tim FRIEDE, Christian STICHERLING a Heikki V HUIKURI

Vydání

Journal of the American Heart Association, Hoboken, Wiley-Blackwell, 2024, 2047-9980

Další údaje

Jazyk

angličtina

Typ výsledku

Článek v odborném periodiku

Obor

30201 Cardiac and Cardiovascular systems

Stát vydavatele

Spojené státy

Utajení

není předmětem státního či obchodního tajemství

Odkazy

Impakt faktor

Impact factor: 5.400 v roce 2022

Organizační jednotka

Lékařská fakulta

UT WoS

001238385200034

Klíčová slova anglicky

appropriate shock; heart failure; implantable cardioverter-defibrillator; death; T-wave alternans

Štítky

Příznaky

Mezinárodní význam, Recenzováno
Změněno: 20. 8. 2024 11:00, Mgr. Tereza Miškechová

Anotace

V originále

Background New methods to identify patients who benefit from a primary prophylactic implantable cardioverter-defibrillator (ICD) are needed. T-wave alternans (TWA) has been shown to associate with arrhythmogenesis of the heart and sudden cardiac death. We hypothesized that TWA might be associated with benefit from ICD implantation in primary prevention. Methods and Results In the EU-CERT-ICD (European Comparative Effectiveness Research to Assess the Use of Primary Prophylactic Implantable Cardioverter-Defibrillators) study, we prospectively enrolled 2327 candidates for primary prophylactic ICD. A 24-hour Holter monitor reading was taken from all recruited patients at enrollment. TWA was assessed from Holter monitoring using the modified moving average method. Study outcomes were all-cause death, appropriate shock, and survival benefit. TWA was assessed both as a contiguous variable and as a dichotomized variable with cutoff points <47 mu V and <60 mu V. The final cohort included 1734 valid T-wave alternans samples, 1211 patients with ICD, and 523 control patients with conservative treatment, with a mean follow-up time of 2.3 years. TWA >= 60 mu V was a predicter for a higher all-cause death in patients with an ICD on the basis of a univariate Cox regression model (hazard ratio, 1.484 [95% CI, 1.024-2.151]; P=0.0374; concordance statistic, 0.51). In multivariable models, TWA was not prognostic of death or appropriate shocks in patients with an ICD. In addition, TWA was not prognostic of death in control patients. In a propensity score-adjusted Cox regression model, TWA was not a predictor of ICD benefit. Conclusions T-wave alternans is poorly prognostic in patients with a primary prophylactic ICD. Although it may be prognostic of life-threatening arrhythmias and sudden cardiac death in several patient populations, it does not seem to be useful in assessing benefit from ICD therapy in primary prevention among patients with an ejection fraction of <= 35%.