SEMRÁD, Bořivoj, Bohumil FIŠER a Nataša HONZÍKOVÁ. Non-linear structure analysis of inter-beat interval data in patients after myocardial infarction. Scripta Medica. Česká republika: MU Faculty of Medicine,Brno, 2000, roč. 73, č. 3, s. 191-194. ISSN 1211-3395.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Non-linear structure analysis of inter-beat interval data in patients after myocardial infarction
Název česky Nelineární strukturální analýza tepových intervalů u nemocných po infarktu myokardu
Název anglicky Non-linear structure analysis of inter-beat interval data in patients after myocardial infarction
Autoři SEMRÁD, Bořivoj (203 Česká republika), Bohumil FIŠER (203 Česká republika) a Nataša HONZÍKOVÁ (203 Česká republika, garant).
Vydání Scripta Medica, Česká republika, MU Faculty of Medicine,Brno, 2000, 1211-3395.
Další údaje
Originální jazyk čeština
Typ výsledku Článek v odborném periodiku
Obor 30201 Cardiac and Cardiovascular systems
Stát vydavatele Česká republika
Utajení není předmětem státního či obchodního tajemství
Kód RIV RIV/00216224:14110/00:00002519
Organizační jednotka Lékařská fakulta
Klíčová slova anglicky myocardial infarction; scaling index;
Štítky Myocardial infarction, scaling index
Změnil Změnila: prof. MUDr. Nataša Honzíková, CSc., učo 1700. Změněno: 19. 6. 2009 16:10.
Anotace
The aim of the present study was to test reliability of the quotint fast scaling index method" of nonlinear dynamics (chaos theory) of heart rate variability. Holter 24-hour ECG recordings in patients after myocardial infarction were analysed. The scaling index alpha, i.e. the state distribution of successive RR intervals in phase space, was calculated of 500 beats at the beginning of each hour and the N(alpha) histogram was constructed as a sum of 24 histograms. The difference between the alpha value calculated for the peak of sinus rhythm and that for ectopic beats was determined. The reliability of this fast method was tested by a comparison of each 24-hour histogram with three relevant 6-hour histograms (night, morning and afternoon). No difference was found in the delta alpha determination from 24-hour and 6-hour periods. The time of recording (morning, afternoon, night) did not play any role, either. It is concluded that this scaling index alpha method is suitable for clinical practice.
Anotace anglicky
The aim of the present study was to test reliability of the quotint fast scaling index method" of nonlinear dynamics (chaos theory) of heart rate variability. Holter 24-hour ECG recordings in patients after myocardial infarction were analysed. The scaling index alpha, i.e. the state distribution of successive RR intervals in phase space, was calculated of 500 beats at the beginning of each hour and the N(alpha) histogram was constructed as a sum of 24 histograms. The difference between the alpha value calculated for the peak of sinus rhythm and that for ectopic beats was determined. The reliability of this fast method was tested by a comparison of each 24-hour histogram with three relevant 6-hour histograms (night, morning and afternoon). No difference was found in the delta alpha determination from 24-hour and 6-hour periods. The time of recording (morning, afternoon, night) did not play any role, either. It is concluded that this scaling index alpha method is suitable for clinical practice.
VytisknoutZobrazeno: 26. 8. 2024 18:00