HONZÍKOVÁ, Nataša, Bohumil FIŠER a Bořivoj SEMRÁD. Critical value of baroreflex sensitivity determined by spectral analysis in risk stratification after myocardial infarction. Pacing and Clinical Electrophysiology. Armonk, New York: Futura Publishing Company, Inc., 2000, roč. 23, č. 11, s. 1965-1967. ISSN 0147-8389.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Critical value of baroreflex sensitivity determined by spectral analysis in risk stratification after myocardial infarction.
Název česky Kritická hodnota citlivosti baroreflexu stanovená spektrální analýzou v rizikové stratifikaci po infarktu myokardu
Autoři HONZÍKOVÁ, Nataša (203 Česká republika, garant), Bohumil FIŠER (203 Česká republika) a Bořivoj SEMRÁD (203 Česká republika).
Vydání Pacing and Clinical Electrophysiology, Armonk, New York, Futura Publishing Company, Inc. 2000, 0147-8389.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 30105 Physiology
Stát vydavatele Spojené státy
Utajení není předmětem státního či obchodního tajemství
Impakt faktor Impact factor: 1.600
Kód RIV RIV/00216224:14110/00:00002637
Organizační jednotka Lékařská fakulta
UT WoS 000165755900063
Klíčová slova anglicky Baroreflex sensitivity; spectral analysis; myocardial infarction; cardiac death; critical value; risk stratification.
Štítky baroreflex sensitivity, cardiac death, critical value, Myocardial infarction, risk stratification., spectral analysis
Změnil Změnila: prof. MUDr. Nataša Honzíková, CSc., učo 1700. Změněno: 17. 6. 2009 14:29.
Anotace
The critical value of baroreflex sensitivity (BRS) was assessed by spectral analysis of spontaneous fluctuations in pulse intervals and blood pressure. Blood pressure was recorded noninvasively (3 min, controlled breathing 0.33 Hz) in 112 patients, 8-18 days after myocardial infarction (MI). Nine patients died during the first year after MI. BRS was determined as the gain between the spectrum of the variability of systolic blood pressure and the cross-spectrum between the variability of pulse intervals and systolic blood pressure at the frequency of 0.1 Hz. Sensitivity, specificity, and the positive predictive value were calculated in the range of 1-10 ms/mmHg in steps of 1 ms/mmHg. The value of BRS above which sensitivity no longer increases and specificity decreases was taken as the optimal value. The optimal critical value was 3 ms/mmHg.
Anotace česky
Kritická hodnota citlivosti baroreflexu (BR) byla stanovena spektrální analýzou kolísání tepových intervalů a krevního tlaku. Krevní tlak byl vyšetřen u 112 pacientů 8-18 dnů po infarktu myokardu. Devět pacientů zemřelo během prvního roku po IM. BRS bylo stanoveno spektrální metodou při frekvenci 0.0 Hz. Sensitivita, specificta a positviní prediktivní hodnota byly určeny v rozmezí 1-10 ms/mmHg v krocích po 1 ms/mmHg. Optimální kritická hodnota byla stanovena 3 ms/mmHg.