PREISLER, J., P. HU, T. REJTAR a B. L. KARGER. Capillary electrophoresis - Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry Using a vacuum deposition Interface. Analytical Chemistry. Washington, D.C., USA: American Chemical Society, 2000, roč. 72, č. 20, s. 4785-4795. ISSN 0003-2700.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Capillary electrophoresis - Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry Using a vacuum deposition Interface
Název česky Kapilární elektroforéza - laserová desorpce/ionizace za účasti matrice s půletovou hmotnostní spektrometrií a rozhraním pro vakuové nanášení
Autoři PREISLER, J. (203 Česká republika, garant), P. HU (840 Spojené státy), T. REJTAR (203 Česká republika) a B. L. KARGER (840 Spojené státy).
Vydání Analytical Chemistry, Washington, D.C., USA, American Chemical Society, 2000, 0003-2700.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10406 Analytical chemistry
Stát vydavatele Spojené státy
Utajení není předmětem státního či obchodního tajemství
Impakt faktor Impact factor: 4.587
Organizační jednotka Přírodovědecká fakulta
UT WoS 000089924800003
Klíčová slova anglicky MALDI; CE; interface; matrix-assisted laser desorption; vacuum; deposition; peptides; proteins; proteome; proteomic; digest
Štítky CE, deposition, digest, interface, MALDI, matrix-assisted laser desorption, peptides, proteins, proteome, proteomic, vacuum
Změnil Změnil: prof. Mgr. Jan Preisler, Ph.D., učo 45329. Změněno: 28. 6. 2009 00:02.
Anotace
An improved vacuum deposition interface for coupling capillary electrophoresis with MALDI/TOF MS has been developed. Liquid samples consisting of analyte and matrix were deposited on a moving tape in the evacuated source chamber of TOF mass spectrometer, enabling a day of continuous analysis without interruption. The vacuum deposition procedure was compared with the dried-droplet method, and it was found that vacuum deposition generated significantly more reproducible signal intensity, eliminating the need for the "sweet spot" searching. In addition, ion suppression caused by hydrophobicity differences in the analytes was reduced. In order to minimize ion suppression further, separation prior to MALDI/MS analysis was employed. The performance of capillary electrophoresis (CE) - MALDI/TOF MS using the vacuum deposition interface was evaluated with a peptide mixture injected at low femtomole levels. All peptides were baseline resolved with separation efficiencies in the range of 250,000 - 400,000 plates/m (2 - 3 second band halfwidth), demonstrating the high separation efficiency of the CE-MALDI/MS coupling.
Anotace česky
Kapilární elektroforéza - laserová desorpce/ionizace za účasti matrice s půletovou hmotnostní spektrometrií a rozhraním pro vakuové nanášení, viz anglický popis.
VytisknoutZobrazeno: 26. 5. 2024 15:36