KANICKÝ, Viktor, Vítězslav OTRUBA and Jean-Michel MERMET. Calibration graphs for Ti, Ta and Nb in sintered tungsten carbide by infrared laser ablation inductively coupled plasma atomic emission spectrometry. Fresenius Journal of Analytical Chemistry. Berlin: Springer-Verlag, 2001, vol. 371, No 7, p. 934-938. ISSN 0937-0633.
Other formats:   BibTeX LaTeX RIS
Basic information
Original name Calibration graphs for Ti, Ta and Nb in sintered tungsten carbide by infrared laser ablation inductively coupled plasma atomic emission spectrometry
Authors KANICKÝ, Viktor (203 Czech Republic, guarantor), Vítězslav OTRUBA (203 Czech Republic) and Jean-Michel MERMET.
Edition Fresenius Journal of Analytical Chemistry, Berlin, Springer-Verlag, 2001, 0937-0633.
Other information
Original language English
Type of outcome Article in a journal
Field of Study 10406 Analytical chemistry
Country of publisher Czech Republic
Confidentiality degree is not subject to a state or trade secret
Impact factor Impact factor: 1.649
RIV identification code RIV/00216224:14310/01:00004732
Organization unit Faculty of Science
UT WoS 000172742900007
Keywords in English Laser ablation; LINA spark; Infrared laser; Inuctively coupled plasma; Atomic emission spectrometry
Tags atomic emission spectrometry, Infrared Laser, Inuctively coupled plasma, laser ablation, LINA spark
Changed by Changed by: prof. RNDr. Viktor Kanický, DrSc., učo 408. Changed: 28/6/2007 16:42.
Abstract
Infrared laser ablation (IR-LA) was studied as a sample introduction technique for the analysis of sintered cobalt-cemented tungsten carbide materials by inductively coupled plasma atomic emission spectrometry (ICP-AES). A Q-switched nanosecond Nd:YAG laser (LINA-Spark Atomizer, LSA Sarl, Cully, Switzerland) based on the Surelite I-20 laser (Continuum, USA) and a Perkin-Elmer Optima 3000 DV ICP system (lateral viewing) were used. The fractionation of cobalt was observed. Linearity of calibration plots was verified at least up to 15 % Ti, 8 % Ta and 3 % Nb. Above 1% (mass %) Ti, Ta and Nb, the repeatability of results was better than 3 % R.S.D. The relative uncertainty at the centroid of the calibration line was in the range from ą 3% to ą 4% for Ti, Ta and Nb with internal standardization by tungsten and up to ą 5% without internal standardization. The limits of detection were 0.004 % Ti, 0.001 % Ta and 0.004 % Nb. The elimination of the cemented hardmetal dissolution procedure is the main advantage of this method.
Links
GA203/00/0415, research and development projectName: Studium interakce laserového záření s práškovými materiály v optické emisní spektrometrii s indukčně vázaným plazmatem
Investor: Czech Science Foundation, The study of interaction of laser radiation with pressed powdered materials for laser ablation inductively coupled plasma atomic emission spectrometry
MSM 143100003, plan (intention)Name: Studium plazmochemických reakcí v neizotermickém nízkoteplotním plazmatu a jeho interakcí s povrchem pevných látek
Investor: Ministry of Education, Youth and Sports of the CR, Study of plasmachemical reactions in non-isothermic low pressure plasma and its interaction with the surface of solid substrates
PrintDisplayed: 30/5/2024 01:21