2002
Automated micro axial tomography of cell nuclei after specific labelling by fluorescence in situ hybridisation
KOZUBEK, Michal, Magdalena SKALNÍKOVÁ, Petr MATULA, Eva BÁRTOVÁ, Joachim RAUCH et. al.Základní údaje
Originální název
Automated micro axial tomography of cell nuclei after specific labelling by fluorescence in situ hybridisation
Autoři
KOZUBEK, Michal (203 Česká republika, garant), Magdalena SKALNÍKOVÁ (203 Česká republika), Petr MATULA (203 Česká republika), Eva BÁRTOVÁ (203 Česká republika), Joachim RAUCH (276 Německo), Friedrich NEUHAUS (276 Německo), Heinz EIPEL (276 Německo) a Michael HAUSMANN (276 Německo)
Vydání
Micron, Amsterdam, Elsevier, 2002, 0968-4328
Další údaje
Jazyk
angličtina
Typ výsledku
Článek v odborném periodiku
Obor
20200 2.2 Electrical engineering, Electronic engineering, Information engineering
Stát vydavatele
Nizozemské království
Utajení
není předmětem státního či obchodního tajemství
Impakt faktor
Impact factor: 1.537
Kód RIV
RIV/00216224:14330/02:00006215
Organizační jednotka
Fakulta informatiky
Klíčová slova anglicky
micro axial tomography; automated microscopy; high-resolution cytometry; FISH imaging; interphase cell nuclei
Štítky
Příznaky
Mezinárodní význam, Recenzováno
Změněno: 6. 5. 2009 10:59, doc. RNDr. Petr Matula, Ph.D.
Anotace
V originále
Micro axial tomography provides a good means for microscopic image acquisition of cells or sub-cellular components like cell nuclei with an improved resolution, because shortcomings of spatial resolution anisotropy in optical microscopy can be overcome. Thus, spatial information of the object can be obtained without the necessity of confocal imaging. Since the very early developments of micro axial tomography a considerable drawback of this method was a complicated image acquisition and processing procedure that requires much operator time. In order to solve this problem the Heidelberg 2pi-tilting device has been mounted to the Brno high-resolution cytometer as an attempt to bring together advanced microscopy and fast automated computer image acquisition and analysis. A special software module that drives all hardware components required for automated micro axial tomography and performs image acquisition and processing has been developed. Also a method for the preparation of cell nuclei attached to glass fibres has been developed that allows for the first time imaging of three-dimensionally conserved, FISH-stained cell nuclei fixed to a glass fibre.
Návaznosti
MSM 143300002, záměr |
|