Immunosensor for the measurement of human serum albumin in urine based on the Spreeta surface plasmon resonance sensor

NAVRÁTILOVÁ, Iva a Petr SKLÁDAL

Základní údaje

Originální název

Immunosensor for the measurement of human serum albumin in urine based on the Spreeta surface plasmon resonance sensor

Autoři

NAVRÁTILOVÁ, Iva (203 Česká republika) a Petr SKLÁDAL (203 Česká republika, garant)

Vydání

Supramolecular Chemistry, USA, Taylor & Francis, 2003, 1061-0278

Další údaje

Jazyk

angličtina

Typ výsledku

Článek v odborném periodiku

Obor

10600 1.6 Biological sciences

Stát vydavatele

Spojené státy

Utajení

není předmětem státního či obchodního tajemství

Impakt faktor

Impact factor: 1.090

Kód RIV

RIV/00216224:14310/03:00008617

Organizační jednotka

Přírodovědecká fakulta

UT WoS

000181576300005

Klíčová slova anglicky

Immunosensor;Human serum albumin;Spreeta
Změněno: 4. 3. 2003 10:16, prof. RNDr. Petr Skládal, CSc.

Anotace

V originále

The application of SPR for the measurement of concentration of human serum albumin (HSA) in urine was studied using the compact integrated SPR sensing system Spreeta. HSA was immobilized via cystamine and glutaraldehyde onto the gold sensing area and a competitive assay for HSA was developed using limited amount of the monoclonal antibody AL-01 in solution. Measurements were carried out in the flow-through mode and the interaction between immobilized HSA and antibody was observed in real time. To obtain reproducible results, different conditions of the measurement (method of immobilization of HSA, data evaluation, concentration of antibody, regeneration procedure) were tested. The calibration curve for clinically relevant concentrations of HSA in urine samples was constructed using 300-times diluted antibody in the form of ascites fluid. The measuring range was between 0.1 and 5 mg/l of HSA, the sensing surface was successfully regenerated and suitable for more than 20 assays. The developed method was tested on real samples of urine; to overcome the non-specific adsorption of urine components, the differential approach was adopted and the measured signal was corrected by subtraction of the response observed in the absence of the antibody.