D 2003

Application of elimination voltammetry with linear scan in bioelectrochemistry

TRNKOVÁ, Libuše

Basic information

Original name

Application of elimination voltammetry with linear scan in bioelectrochemistry

Authors

TRNKOVÁ, Libuše (203 Czech Republic, guarantor)

Edition

Sao Paulo, Brazil, The role of electrochemistry in sustained development of modern societies, 54 th ISE Meeting, p. 92-92, 1 pp. 2003

Publisher

Uprema

Other information

Language

English

Type of outcome

Proceedings paper

Field of Study

10405 Electrochemistry

Country of publisher

Brazil

Confidentiality degree

is not subject to a state or trade secret

RIV identification code

RIV/00216224:14310/03:00008232

Organization unit

Faculty of Science

Keywords in English

Voltammetric methods; elimination voltammetry with linear scan (EVLS); elimination functions; adsorbed species; mercury and solid electrodes; resolution of reduction and oxidation signals in oligo- and poly-nucleotides
Changed: 20/6/2008 12:04, prof. RNDr. Libuše Trnková, CSc.

Abstract

In the original language

Elimination Voltammetry with Linear Scan (EVLS) is able to eliminate one or two selected current components from a total linear sweep voltammetric current. This is achieved by using elimination function obtained by the linear combination of total currents measured at different scan rates. In comparison with cyclic voltammetry (CV) or linear sweep voltammetry (LSV), the EVLS provides specific advantages: (a) expanded the available electrode potential range, (b) increased current sensitivity, and (c) improved peak resolution. The last two benefits result from the fact that the elimination of kinetic and charging currents decreases the irreversible current width and increases the peak height. The effect is particularly pronounced in the case where adsorption is involved. For the electroactive substance adsorbed or interacting with the electrode surface, the elimination function gives a well detectable peak-counterpeak signal which can be successfully used to analyze overlapped reduction or oxidation signals. The elimination procedure was applied to the analysis of nucleic acids (NA) and short synthetic homo- and hetero-deoxyoligonucleotides (ODNs) containing adenine (A), cytosine (C) and guanine (G). While only an incompletely developed peak can be seen on CV curves, the elimination function eliminating kinetic and charging currents and conserving a diffusion current gives well developed sharp peak-counterpeak signals. The height and position of these signals were affected by pH, buffer components, the content of the bases, and the time of accumulation. The EVLS results showed that the elimination voltammetric signal of C is separated from the signal of A, and the elimination signals of A and C reflect their sequences in ODNs molecules. Using selected elimination functions the EVLS is able to detect the nature of electrode processes. The EVLS, particularly in combination with adsorptive stripping procedure, is a promising tool for qualitative and quantitative electrochemical studies of oligo- and polynucleotides, including hairpins and nucleic acids.

Links

GA203/02/0422, research and development project
Name: Nové směry v elektrochemii nukleových kyselin a jejich aplikace v chemii životního prostředí
Investor: Czech Science Foundation, New trends in electrochemistry of nucleic acids and their applications in enviromental chemistry
GV204/97/K084, research and development project
Name: Elektrody modifikované nukleovými kyselinami a bílkovinami. Nové nástroje v biochemickém a biomedicínském výzkumu
Investor: Czech Science Foundation, Electrodes modified with nucleic acids and proteins. New tools in biochemical and biomedical research
IAA1163201, research and development project
Name: Využití adsorptivní přenosové a eliminační techniky pro elektrochemickou analýzu oligonukleotidů a nukleových kyselin
Investor: Academy of Sciences of the Czech Republic, Application of adsorptive transfer and elemination techniques in oligonucleotides and nucleic acids analysis.