2004
Square wave and elimination voltammetric analysis of azidothymidine in the presence of oligonucleotides and chromosomal DNA
TRNKOVÁ, Libuše, René KIZEK a Jan VACEKZákladní údaje
Originální název
Square wave and elimination voltammetric analysis of azidothymidine in the presence of oligonucleotides and chromosomal DNA
Název česky
Square wave a eliminační voltametrická analýza azidothymidinu v přítomnosti oligonukleotidů a chromosomální DNA
Autoři
TRNKOVÁ, Libuše (203 Česká republika, garant), René KIZEK (203 Česká republika) a Jan VACEK (203 Česká republika)
Vydání
Bioelectrochemistry, The Netherlands, Elsevier, 2004, 1567-5394
Další údaje
Jazyk
angličtina
Typ výsledku
Článek v odborném periodiku
Obor
10405 Electrochemistry
Stát vydavatele
Nizozemské království
Utajení
není předmětem státního či obchodního tajemství
Impakt faktor
Impact factor: 2.261
Kód RIV
RIV/00216224:14310/04:00011180
Organizační jednotka
Přírodovědecká fakulta
UT WoS
000221786900007
Klíčová slova anglicky
Azidothymidine (AZT); Square wave voltammetry (SWV); Linear sweep voltammetry (LSV); Elimination voltammetry with linear scan (EVLS); Hanging mercury drop electrode (HMDE); oligonucleotides; PCR product; chromosomal DNA
Štítky
Změněno: 15. 2. 2005 08:32, prof. RNDr. Libuše Trnková, CSc.
V originále
Azidothymidine (AZT, 3-azido-3-deoxythymidine, Zidovudine, Retrovir) is an approved and widely used antiretroviral drug for the treatment of human immunodeficiency virus (HIV) infection. Dynamic electrochemical methods, have been employed for the fast and inexpensive determination of this drug in natural samples. The electrochemical signal of AZT, resulting from the reduction of azido group, was studied by square wave voltammetry (SWV), linear sweep voltammetry (LSV) and elimination voltammetry with linear scan (EVLS) using a hanging mercury drop electrode (HMDE). This paper explores the possibility of determining AZT in the presence of native (dsDNA) or denatured calf thymus DNA (ssDNA), and/or some synthetic oligodeoxynucleotides (ODNs). The detection limit of AZT in the absence and in the presence of ssDNA (10 mg/mL) is 1 nM and 250 nM, respectively. It was found that the signal of AZT is not substantially affected by the presence of DNA. We can therefore assume that the electrons are transferred through the adsorption layer of nucleic acids. By using the elimination procedure, both irreversible reduction signals of AZT and DNA are augmented. Moreover, the elimination signal in the peak-counterpeak form may indicate the adsorption of the analytes on the electrode surface preceding an electron transfer.
Česky
Square wave a eliminační voltametrická analýza azidothymidinu v přítomnosti oligonukleotidů a chromosomální DNA
Návaznosti
GA203/02/0422, projekt VaV |
| ||
IAA1163201, projekt VaV |
|