2004
The immunosensors for measurement of 2,4-dichlorophenoxyacetic acid based on electrochemical impedance spectroscopy
NAVRÁTILOVÁ, Iva a Petr SKLÁDALZákladní údaje
Originální název
The immunosensors for measurement of 2,4-dichlorophenoxyacetic acid based on electrochemical impedance spectroscopy
Název česky
Imunosensor pro stanovení 2,4-dichlorofenoxyoctové kyseliny využívající elektrochemickou impedanční spektroskopii
Autoři
NAVRÁTILOVÁ, Iva (203 Česká republika) a Petr SKLÁDAL (203 Česká republika, garant)
Vydání
Bioelectrochemistry, The Netherlands, Elsevier, 2004, 1567-5394
Další údaje
Jazyk
angličtina
Typ výsledku
Článek v odborném periodiku
Obor
10600 1.6 Biological sciences
Stát vydavatele
Česká republika
Utajení
není předmětem státního či obchodního tajemství
Impakt faktor
Impact factor: 2.261
Kód RIV
RIV/00216224:14310/04:00010107
Organizační jednotka
Přírodovědecká fakulta
UT WoS
000221786300002
Klíčová slova anglicky
Impedance; Immunosensor; Herbicide
Štítky
Změněno: 18. 1. 2005 10:23, prof. RNDr. Petr Skládal, CSc.
V originále
Electrochemical impedance spectroscopy was evaluated for the direct determination of herbicide 2,4-dichlorophenoxyacetic acid (2,4-D). Specific antibody against 2,4-D was immobilised onto different gold electrodes. Several methods of antibody immobilisation by covalent linkage to modified surface were studied. Self-assembled monolayers formed using thiocompounds as cystamine, 4-aminothiophenol (ATPh), 3,3'-dithiopropionic acid di(N-succinimidyl ester) (DTSP) and 11-mercaptoundecanoic acid (MUA) were chosen for the sensing surface activation. Three different sensor types were tested: screen-printed disc and finger-like structures and interdigitated array (IDA) electrodes produced by lithography. The measurements were carried out in a stationary arrangement and the reaction between hapten and the immobilised antibody was observed on-line. Changes of impedance parameters were evaluated and the best immobilisation technique (using 4-aminothiophenol) was chosen for further measurements. Impedance changes due to immunocomplex formation were evaluated and the possibility of direct monitoring of 2,4-D binding to the antibody was demonstrated at a fixed frequency.
Česky
Pro přímé stanovení herbicidu 2,4-D byla využita elektroimpedanční spektroskopie. Protilátky proti 2,4-D byly navázány na zlaté elektrody použitím různých monovrstev thiosloučenin (MUA, DTSP, cystamin, aminothiofenol). Byly využity sensory připravené sítotiskem i litografickou technologií. Byla sledována změna impedance sensorů v přítomnosti analytu.
Návaznosti
OC 518.30, projekt VaV |
|