Multienzyme electrochemical array sensor for determination of phenols and pesticides
SOLNÁ, Renáta, Svetlana SAPELNIKOVA, Petr SKLÁDAL, Margarethe WINTHER-NIELSEN, Charlotte CARLSSON et. al.Základní údaje
Originální název
Multienzyme electrochemical array sensor for determination of phenols and pesticides
Název česky
Multienzymové elektrochemické sensory pro stanovení fenolů a pesticidů
Autoři
SOLNÁ, Renáta (203 Česká republika), Svetlana SAPELNIKOVA (643 Rusko), Petr SKLÁDAL (203 Česká republika, garant), Margarethe WINTHER-NIELSEN (208 Dánsko), Charlotte CARLSSON (752 Švédsko), Jenny EMNEUS (752 Švédsko) a Tautgirdas RUZGAS (440 Litva)
Vydání
Talanta, The Netherlands, Elsevier Science, 2005, 0039-9140
Další údaje
Jazyk
angličtina
Typ výsledku
Článek v odborném periodiku
Obor
10600 1.6 Biological sciences
Stát vydavatele
Česká republika
Utajení
není předmětem státního či obchodního tajemství
Odkazy
Impakt faktor
Impact factor: 2.391
Kód RIV
RIV/00216224:14310/05:00012356
Organizační jednotka
Přírodovědecká fakulta
UT WoS
000225381900009
Klíčová slova anglicky
amperometric screen-printed biosensor; flow-injection analysis; steady state system; tyrosinase; peroxidase; cholinesterase; phenols; pesticides; wastewater
Štítky
Změněno: 7. 6. 2005 16:06, prof. RNDr. Petr Skládal, CSc.
V originále
The screen-printed four-electrode system was used as the amperometric transducer for determination of phenols and pesticides using immobilised tyrosinase, peroxidase, acetylcholinesterase and butyrylcholinesterase. Acetylthiocholine chloride was chosen as substrate for cholinesterases to measure inhibition by pesticides, hydrogen peroxide served as co-substrate for peroxidase to measure phenols. The compatibility of hydrolases and oxidoreductases working in the same array was studied. The detection of p-cresol, catechol and phenol as well as of pesticides including carbaryl, heptenophos and fenitrothion was carried out in flow-through and steady state arrangements. In addition, the effects of heavy metals (Cu2+, Cd2+, Fe3+), fluoride (NaF), benzene and dimethylsulphoxide on cholinesterase activities were evaluated. It was demonstrated that electrodes modified with hydrolases and oxidoreductases can function in the same array. The achieved R.S.D. values obtained for the flow system were below 4% for the same sensor and less than 10% within a group of five sensors. For the steady state system, R.S.D.s were approximately twice higher. One assay was completed in less than 6 min. The limit of detection for catechol using tyrosinase was equal to 0.35 and 1.7 ěM in the flow and steady state systems, respectively. On the contrary, lower limits of detection for pesticides were achieved in the steady state systemcarbaryl 26 nM, heptenophos 14 nM and fenitrothion 0.58 uM.
Česky
Stotiskový čtyřkanálový sensor sloužil jako amperometrický převodník pro stanovení fenolů a pesticidů použitím tyrosinasy, peroxidasy, cholinesteras AChE a BChE. Byla studována kompatibilita těchto enzymů při imobilisaci na stejném sensoru. Detekované látky zahrnovaly kresol, katechol, fenol a pesticidy jako karbaryl, heptenofos a fenitrothion. Měření byla prováděna v průtočném i míchaném uspořádání. Doba stanovení byla 15 min a limity detekce v oblasti mikromolárních (fenoly) a nanomolárních (pesticidy) koncentrací.
Návaznosti
GA525/97/0924, projekt VaV |
| ||