Detailed Information on Publication Record
2004
Application of Dipon, (1,4,8,11-tetraazacyclotetradecane-4,11-bis(methylphosphonic acid) as selective complexing agent for determination of copper(II)
SVOBODOVÁ, Ivona, Přemysl LUBAL, Petr HERMANN, Jan KOTEK, Josef HAVEL et. al.Basic information
Original name
Application of Dipon, (1,4,8,11-tetraazacyclotetradecane-4,11-bis(methylphosphonic acid) as selective complexing agent for determination of copper(II)
Name in Czech
Application of Dipon, (1,4,8,11-tetraazacyclotetradecane-4,11-bis(methylphosphonic acid) as selective complexing agent for determination of copper(II)
Authors
SVOBODOVÁ, Ivona (203 Czech Republic), Přemysl LUBAL (203 Czech Republic, guarantor), Petr HERMANN (203 Czech Republic), Jan KOTEK (203 Czech Republic) and Josef HAVEL (203 Czech Republic)
Edition
Journal of Inclusion Phenomena and Macrocyclic Chemistry, Dordrecht, Kluwer, 2004, 0923-0750
Other information
Language
English
Type of outcome
Článek v odborném periodiku
Field of Study
10406 Analytical chemistry
Country of publisher
Netherlands
Confidentiality degree
není předmětem státního či obchodního tajemství
Impact factor
Impact factor: 0.825
RIV identification code
RIV/00216224:14310/04:00011010
Organization unit
Faculty of Science
UT WoS
000221931100003
Keywords in English
cyclam derivative; macrocyclic ligand; 1;4;8;11-tetraazacyclotetradecane-1;8-bis(methylphosphonic acid); microscale copper(II) determination; phosphonate complexes; UV/VIS spectrophotometric end-point detection
Tags
Změněno: 8/4/2010 20:14, prof. RNDr. Přemysl Lubal, Ph.D.
V originále
A new macrocyclic ligand, 1,4,8,11-tetraazacyclotetradecane-1,8-bis(methylphosphonic acid) (dipon), is selective complexing agent for copper(II) over other transition metal ions. The ligand was tested for analytical applications of copper( II) determination. Spectrophotometric determination under optimal experimental conditions (-log [H+] = 5.5, c(L) approximate to 5 x 10(-4) mol L-1, lambda 310 nm) is valid in dynamic range (5-200) x 10(-6) mol L-1 with detection limit 2.2 x 10(-6) mol L-1, i.e. 0.14 mug ml(-1). Volumetric determination of copper(II) with standardized dipon solution was used for copper(II) determination at micromolar concentration level without any necessity to sequester interfering metal ions. A sharp end point of titration was detected by UV/VIS spectrophotometry. Both methods were tested on artificial and real samples (spiked mineral water, alloys) and gave satisfactory results without any systematic error. The advantage of both methods is their simplicity, and rapidity.
In Czech
Nový makrocyklický ligand, 1,4,8,11-tetraazacyclotetradecane-1,8-bis(methylfosfonévá kyselina) (dipon), je selektivní chelatační činidlo pro stanovení měďnatých iontů v přítomosti iontů jiných přechodných kovů. Ligand byl testován pro analytické stanovení měďnatých iontů za optimálních experimentálních podmínek (-log [H+] = 5.5, c(L) approximate to 5 x 10(-4) mol L-1, lambda 310 nm) pro dynamický koncentrační rozsah (5-200) x 10(-6) mol L-1 s detekčním limitem 2.2 x 10(-6) mol L-1, t.j. 0.14 mug ml(-1). Volumetrické stanovení Cu(II) pomocí odměrného dipon roztoku bylo použito pro její stanovení v mikromolárních koncentracích bez nutnosti maskovat interferující ionty kovů. Ostrý ekvivalenční bond byl detekován pomocí UV/VIS spektrofotometrie. Obě metody byly použity pro analýzu umělých a reálných vzorků a poskytly shodné výsledky nezatížené žádnou systematickou chybou. Výhoda obou metod je v jejich jednoduchosti a rychlosti.
Links
GA203/02/0493, research and development project |
| ||
GA203/03/0168, research and development project |
| ||
MSM 143100011, plan (intention) |
| ||
OC D18.001, research and development project |
|