2005
Amperometric screen-printed biosensor arrays with co-immobilised oxidoreductases and cholinesterases
SOLNÁ, Renáta, Eva DOCK, Alexander CHRISTENSON, Margrethe WINTER-NIELSEN, Christine CARLSSON et. al.Základní údaje
Originální název
Amperometric screen-printed biosensor arrays with co-immobilised oxidoreductases and cholinesterases
Název česky
Amperometrické sítotisková biosensorová pole s koimobilisovanými oxidoreduktasami a cholinesterasami
Autoři
SOLNÁ, Renáta (203 Česká republika), Eva DOCK (752 Švédsko), Alexander CHRISTENSON (752 Švédsko), Margrethe WINTER-NIELSEN (208 Dánsko), Christine CARLSSON (752 Švédsko), Jenny EMNÉUS (752 Švédsko), Tautgirdas RUZGAS (752 Švédsko) a Petr SKLÁDAL (203 Česká republika, garant)
Vydání
Analytica Chimica Acta, Amsterdam, Elsevier Science Publishers, 2005, 0003-2670
Další údaje
Jazyk
angličtina
Typ výsledku
Článek v odborném periodiku
Obor
10600 1.6 Biological sciences
Stát vydavatele
Česká republika
Utajení
není předmětem státního či obchodního tajemství
Impakt faktor
Impact factor: 2.760
Kód RIV
RIV/00216224:14310/05:00013673
Organizační jednotka
Přírodovědecká fakulta
UT WoS
000226455600002
Klíčová slova anglicky
amperometric multienzyme sensor; steady state system; cholinesterase; oxidoreductase; phenoks; pesticides; wastewater; multivariate-analysis
Štítky
Změněno: 7. 6. 2005 16:04, prof. RNDr. Petr Skládal, CSc.
V originále
Amperometric screen-printed biosensor arrays for detection of pesticides (organophosphates and carbamates) and phenols have been developed. Cholinesterases (AChE and BChE), tyrosinase (TYR), peroxidases (SBP. soybean and HRP. horseradish) and cellobiose dehydrogenase (CDH) were combined on the same array consisting of one Ag/AgCl reference electrode surrounded by eight radially distributed working electrodes of either carbon or platinum. Mainly cross-linking with glutaraldehyde was employed for enzyme immobilisation. The substrates for the enzymes were acetylthiocholine for cholinesterases (ChEs), cellobiose for CDH and hydrogen peroxide for peroxidases. Hydrogen peroxide was generated in the presence of glucose by co-immobilised glucose oxidase (GOx). All measurements were performed in an electrochemical steady state system specially constructed for eight channel screen-printed electrode arrays. The achieved relative standard deviation values calculated for different enzyme substrates (10 measurements) were typically below 7% and one assay was completed within less than 10 min. The detection limits for pesticides and phenols were in the nanomolar and micromolar ranges, respectively. The developed biosensor array was evaluated on wastewater samples. To simplify interpretation of results. the measured data were created with multivariate analysis-principal component analysis (PCA).
Česky
Amperometrické sítotiskové multielektrodové biosensory byly připraveny použitím cholinesteras (AChE a BChE), tyrosinasy, celobiosa dehydrogenasy a peroxidas (křenová a sojová) na jediném sensoru. Byly optimalisovány podmínky měření. Testované vzorky odpadních vod pak byly klasifikovány pomocí chemometrické multivariační analysy.
Návaznosti
MSM0021622413, záměr |
|