J 2006

Piezoelectric immunosensors for polychlorinated biphenyls operating in aqueous and organic phases

PŘIBYL, Jan, Maria HEPEL a Petr SKLÁDAL

Základní údaje

Originální název

Piezoelectric immunosensors for polychlorinated biphenyls operating in aqueous and organic phases

Název česky

Piezoelektrický imunosensor pro polychlorované bifenyly fungující ve vodném prostředí i v organických rozpouštědlech

Autoři

PŘIBYL, Jan (203 Česká republika), Maria HEPEL (840 Spojené státy) a Petr SKLÁDAL (203 Česká republika, garant)

Vydání

Sensors and Actuators B Chemical, Amsterdam (Holandsko), Elsevier, 2006, 0925-4005

Další údaje

Jazyk

angličtina

Typ výsledku

Článek v odborném periodiku

Obor

10600 1.6 Biological sciences

Stát vydavatele

Nizozemské království

Utajení

není předmětem státního či obchodního tajemství

Impakt faktor

Impact factor: 2.331

Kód RIV

RIV/00216224:14310/06:00016802

Organizační jednotka

Přírodovědecká fakulta

UT WoS

000235593200044

Klíčová slova anglicky

Biosensor; Toluene; Quartz crystal nanobalance

Příznaky

Mezinárodní význam, Recenzováno
Změněno: 16. 11. 2006 17:20, prof. RNDr. Petr Skládal, CSc.

Anotace

V originále

The piezoelectric quartz crystal operating in the active mode was used as a transducer for construction of immunosensors for determination polychlorinated biphenyls(PCB). An apparatus for flow-through measurements with piezosensors in pure organic phase was constructed. The anti-PCB polyclonal antibody was immobilized in an oriented way via protein A on a smooth gold surface. The antibody high cross-reactivity for 2,4,4'-trichlorobiphenyl, 4,4'-dichlorobiphenyl and 3,3,4,4'-tetrachlorbiphenyl allowed for a specific determination of these congeners in samples. PCBs were determined either directly or using competition with a tracer, synthesized from polystyrene particles by covalent attachment of 4,4'-dichlorobiphenyl (DCB). The direct piezoelectric immunosensor operated in phosphate buffer with 5% dimethylsulphoxide. It was possible to detect coplanar PCBs in the range 1-50ppm. A higher detection limit is compensated here by the low cost and short time of analysis, below 20 min. The same immunorecognition layer can be used repeatedly. Furthermore, kinetic analysis based on a non-linear fitting of the recorded binding transients allowed for a detailed characterization of immunoaffinity interactions. For the more sensitive competitive assay, experiments were carried out directly in pure organic solvents. The most hydrophobic solvent, toluene, was selected due to the highest signal responses. The immunoreaction proceeded also quite well in the presence of dichloromethane and chloroform. However, rather low responses were obtained with acetonitrile and dimethylsulphoxide. The optimized method allowed us to detect PCBs in the range from 6 ppb to 1 ppm within 30 min using raw toluene extracts of soil samples without any purification or pre-concentration steps.

Česky

Byl vyvinut piezoelektrický imunosensor s imobilizovanou protilátkou specifickou vůči polychlorovaným bifenylům. Sensor umožňuje přímé i kompetitivní měření PCB, je možné pracovat v nevodném prostředí, což je zvláště vhodné pro nepolární látky.

Návaznosti

MSM0021622413, záměr
Název: Proteiny v metabolismu a při interakci organismů s prostředím