TELNAROVÁ, Magdaléna, Kateřina PAPEŽOVÁ, Tomáš NĚMEC a Zdeněk GLATZ. Electrophoretically mediated microanalysis as a tool for the enzyme study. In CD of the abstracts of the 29th international symposium on capillary chromatography. Belgium: T. Sandra and P. Sandra, 2006, s. x, 1 s.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Electrophoretically mediated microanalysis as a tool for the enzyme study
Název česky Studium enzymů pomocí metody EMMA
Autoři TELNAROVÁ, Magdaléna, Kateřina PAPEŽOVÁ, Tomáš NĚMEC a Zdeněk GLATZ.
Vydání Belgium, CD of the abstracts of the 29th international symposium on capillary chromatography, od s. x, 1 s. 2006.
Nakladatel T. Sandra and P. Sandra
Další údaje
Originální jazyk angličtina
Typ výsledku Stať ve sborníku
Obor 10600 1.6 Biological sciences
Stát vydavatele Itálie
Utajení není předmětem státního či obchodního tajemství
Organizační jednotka Přírodovědecká fakulta
Klíčová slova anglicky cytochromes P450; diclofenac; MEKC
Štítky cytochromes P450, diclofenac, MEKC
Změnil Změnil: prof. RNDr. Zdeněk Glatz, CSc., učo 1865. Změněno: 19. 5. 2009 18:44.
Anotace
Fourteen years ago a new application for the evaluation of enzymatic reactions in capillary electrophoresis (CE) was proposed and developed, electrophoretically mediated microanalysis (EMMA). In this methodology, the capillary is used not only as a separation medium but also as a reaction chamber. Substrate(s) and enzyme are introduced in the capillary as distinct plugs, the first analyte injected being the one with the lower electrophoretic mobility. Upon the application of an electric field, these two zones interpenetrate due the differences in their electrophoretic mobilities. Enzymatic reaction takes place and the resultant reaction product(s) and the unreacted substrate(s) are electrophoretically transported towards detector, where they are individually detected. In this communication the EMMA methodology was applied to complex kinetic study of haloalkane dehalogenase from Sphingomonas paucimobilis UT26. The Michaelis constants for different substrates, the inhibition constant for inhibitor 1,2-dichloroethane, substrate inhibition of 1,2-dibromoethane and the effect of temperature on enzymatic reaction were evaluated by means of the EMMA methodology with partial filling technique. EMMA combines all advantages of CE in the study of enzyme kinetics. The minimal sample and reagent requirements as well as high separation efficiency of CE are fully utilŹized. The absence of manual procedures and complete automation miniŹmize the risk of cross contamination and strongly reduce the assay cost.
Anotace česky
V píspvku byla prezentována možnost využití metody EMMA pi studiu enzym.
Návaznosti
GA203/06/0047, projekt VaVNázev: Využití kapilární elektroforézy pro studium metabolismu léčiv
Investor: Grantová agentura ČR, Využití kapilární elektroforézy pro studium metabolismu léčiv
LC06023, projekt VaVNázev: Integrované bioanalytické technologie pro mikroanalýzy a diagnostiku s využitím LIF a hmotnostní spektrometrie
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, Integrované bioanalytické technologie pro mikroanalýzy a diagnostiku s využitím LIF a hmotnostní spektrometrie
MSM0021622413, záměrNázev: Proteiny v metabolismu a při interakci organismů s prostředím
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, Proteiny v metabolismu a při interakci organismů s prostředím
VytisknoutZobrazeno: 28. 7. 2024 11:22