Determination of molecular mass distribution of silicone oils by supercritical fluid chromatography, matrix-assisted laser desorption ionization time-of-flight mass spectrometry and their off-line combination
CHMELÍK, Josef, Josef PLANETA, Pavel ŘEHULKA a Josef CHMELÍKZákladní údaje
Originální název
Determination of molecular mass distribution of silicone oils by supercritical fluid chromatography, matrix-assisted laser desorption ionization time-of-flight mass spectrometry and their off-line combination
Autoři
CHMELÍK, Josef, Josef PLANETA, Pavel ŘEHULKA a Josef CHMELÍK
Vydání
Journal of Mass Spectrometry, John Wiley & Sons, Ltd. 2001, 1076-5174
Další údaje
Typ výsledku
Článek v odborném periodiku
Utajení
není předmětem státního či obchodního tajemství
Impakt faktor
Impact factor: 2.685
Organizační jednotka
Přírodovědecká fakulta
UT WoS
000170299700007
Klíčová slova anglicky
gel-permeation chromatography; MALDI-TOF; synthetic-polymers; polydispersity; fractionation; performance
Štítky
Příznaky
Mezinárodní význam, Recenzováno
Změněno: 10. 1. 2007 19:26, Mgr. Josef Chmelík, Ph.D.
Anotace
V originále
Silicone oil samples were characterized by supercritical fluid chromatography (SFC), matrix-assisted laser desorption ionization-time-of-flight mass spectrometry (MALDI-TOF MS), and their off-line combination. SFC was used to separate samples of silicone oils on micropacked capillary columns. The fractions for the identification studies were obtained from SFC runs at defined time intervals, when the restrictor was pulled out from the chromatographic flame ionization detector (FID) and inserted into a glass vial with acetone. MALDI-TOF MS was used for the identification of individual oligomers in the fractions separated. The molecular mass distributions determined based on SFC and MALDI-TOF MS measurements were compared. From this comparison, it follows that the results are in good agreement. However, certain differences were observed: MALDI-TOF MS was capable of detecting somewhat larger oligomers than the SFC-FID, but the lower molecular mass oligomers were not present in the MALDI spectra. Differences in the region of lower molecular masses can be explained by evaporation of the more volatile low molecular mass oligomers resulting from heating of the sample during the MALDI-TOF MS measurements as a result of the absorption of the laser shot energy. The fact that no high mass discrimination effects of the MALDI-TOF MS measurements, compared with SFC, were observed is very promising for further applications of MALDI-TOF MS in characterizing synthetic polymers of moderate polydispersity.