Detailed Information on Publication Record
2006
Amplified oligonucleotide sensing in microliter volumes containing copper ions by solution streaming
HASOŇ, Stanislav and Vladimír VETTERLBasic information
Original name
Amplified oligonucleotide sensing in microliter volumes containing copper ions by solution streaming
Name in Czech
Zesílení citlivosti detekce oligonukleotidů v mikrolitrových objemech obsahujících ionty mědi prouděním roztoku
Authors
HASOŇ, Stanislav (203 Czech Republic) and Vladimír VETTERL (203 Czech Republic, guarantor)
Edition
Analytical Chemistry, USA, AMER CHEMICAL SOC, 1155 16TH ST, NW, WAS, 2006, 0003-2700
Other information
Language
English
Type of outcome
Článek v odborném periodiku
Field of Study
10405 Electrochemistry
Country of publisher
Czech Republic
Confidentiality degree
není předmětem státního či obchodního tajemství
Impact factor
Impact factor: 5.646
RIV identification code
RIV/00216224:14310/06:00015529
Organization unit
Faculty of Science
UT WoS
000239017700055
Keywords in English
cathodic stripping voltammetry; graphite electrodes; DNA hybridization; magnetic nanoparticles; oligodeoxynucleotides;
Tags
Tags
International impact, Reviewed
Změněno: 27/1/2007 15:21, prof. RNDr. Vladimír Vetterl, DrSc.
V originále
A simple, cost-effective design for amplifying oligodeoxynucleotide (ODN) sensing, in microliter ODN volumes containing copper ions, by solution streaming ( bubbling)is presented. The inert gas streaming ( bubbling) at a constant pressure of 0.04 bar drives the motion of a 30 microliter ODN droplet containing a three-electrode circuit ( inverted drop microcell), and in the presence of copper ions offers an similar to 50-times improvement in the detection of ODN samples. The detection of ODNs at the carbon paste electrode is based on the enhancement of the oxidation peaks of purine bases ( adenine and guanine) by the anodic stripping of the electrochemically accumulated complex of Cu(I) with purine base residues of acid hydrolyzed ODN samples ( Cu(I)-ahODN complex).
In Czech
Je popsána levná metoda zvýšení citlivosti detekce oligonukleotidů v mikrolitrových objemech obsahujících ionty mědi probubláváním roztoku. Proud inertního plynu probublává za konstatního tlaku 0.04 bar 30 mikrolitrovou kapku oligodeoxynukleotidu (ODN) obsahující tříelektrodový system.. V přítomnosti Cu iontů to umožňuje až 50ti násobné zvýšení ciltlivosti detekce ODN. Detekce ODN na uhlíkové pastové elektrodě je založena na zvýšení oxidačního píku purinových bazí (adenin a guanin).
Links
IAA4004404, research and development project |
|