a 2008

Simulation of fluorescence image formation in 3D image cytometry

KOZUBEK, Michal, David SVOBODA, Marek KAŠÍK, Martin MAŠKA, Jan HUBENÝ et. al.

Základní údaje

Originální název

Simulation of fluorescence image formation in 3D image cytometry

Název česky

Simulace formování fluorescenčního obrazu v 3D obrazové cytometrii

Autoři

KOZUBEK, Michal, David SVOBODA, Marek KAŠÍK, Martin MAŠKA, Jan HUBENÝ, Stanislav STEJSKAL, Michal SEEMAN a Pavel ZEMČÍK

Vydání

XXIV International Congress of International Society for Analytical Cytology, 2008

Další údaje

Jazyk

angličtina

Typ výsledku

Konferenční abstrakt

Obor

20200 2.2 Electrical engineering, Electronic engineering, Information engineering

Stát vydavatele

Maďarsko

Utajení

není předmětem státního či obchodního tajemství

Organizační jednotka

Fakulta informatiky

Klíčová slova anglicky

simulation; image formation; 3D image cytometry

Příznaky

Mezinárodní význam
Změněno: 12. 6. 2008 13:19, prof. RNDr. Michal Kozubek, Ph.D.

Anotace

V originále

Image cytometry still meets the problem of the quality of cell image analysis results. The majority of 2D as well as 3D cell image data acquired using fluorescence microscopy is typically of not very good quality (due to degradations caused by cell preparation, optics and electronics). That is why image processing algorithms applied to this data typically offer imprecise and unreliable results. As the ground truth (GT) for given image data is obviously not available the outputs of different image analysis methods can be neither verified nor compared to each other. In some papers, this problem is partially solved by estimating GT by experts in the field (biologists or physicians). However, in many cases such GT estimate is very subjective and strongly varies among different experts. In order to overcome these difficulties we have created a toolbox that can generate 3D models of artificial biological objects (cells and their components) along with their corresponding images degraded by specific optics and electronics. Image analysis methods can then be applied to such simulated image data. The analysis results (such as segmentation or measurement results) can be compared with GT derived from input models of objects (or measurements on them). In this way, image analysis methods can be compared to each other and their quality (based on difference from GT) can be computed. The present version of the simulation toolbox can generate cells in 3D using deformation of simple shapes and adding texture to the cell interior. Further, it can simulate optical degradations using convolution with supplied point spread function as well as CCD camera artifacts such as impulse hot pixel noise, additive readout-noise or Poisson photon-shot noise. We have also dealt with the task of evaluating the plausibility of the simulated images in terms of their similarity to real image data. We have tested several similarity criteria such as visual comparison, intensity histograms, central moments, frequency analysis and entropy. The simulation toolbox will be made freely available via simple web interface.

Návaznosti

LC535, projekt VaV
Název: Dynamika a organizace chromosomů během buněčného cyklu v normě a patologii
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, Dynamika a organizace chromosomů během buněčného cyklu v normě a patologii
2B06052, projekt VaV
Název: Vytipování markerů, screening a časná diagnostika nádorových onemocnění pomocí vysoce automatizovaného zpracování multidimenzionálních biomedicínských obrazů (Akronym: Biomarker)
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, Vytipování markerů, screening a časná diagnostika nádorových onemocnění pomocí vysoce automatizovaného zpracování multidimenzionálních biomedicínských obrazů