ČTVRTNÍČKOVÁ, Tereza, Luisa María CABALÍN, Javier LASERNA a Viktor KANICKÝ. Comparison of double-pulse and single-pulse laser-induced breakdown spectroscopy techniques in the analysis of powdered samples of silicate raw materials for brick-and-tile industry. Spectrochimica Acta Part B: Atomic Spectroscopy. Amsterdam: Elsevier, 2008, roč. 63, č. 1, s. 42-50. ISSN 0584-8547.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Comparison of double-pulse and single-pulse laser-induced breakdown spectroscopy techniques in the analysis of powdered samples of silicate raw materials for brick-and-tile industry
Název česky Srovnání double-pulse a single-pulse techniky spektroskopie laserem buzeného plazmatu v analýze práškových vzorků silikátových surovin pro průmysl keramiky a stavebních hmot
Autoři ČTVRTNÍČKOVÁ, Tereza (203 Česká republika), Luisa María CABALÍN (724 Španělsko), Javier LASERNA (724 Španělsko) a Viktor KANICKÝ (203 Česká republika, garant).
Vydání Spectrochimica Acta Part B: Atomic Spectroscopy, Amsterdam, Elsevier, 2008, 0584-8547.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10406 Analytical chemistry
Stát vydavatele Nizozemské království
Utajení není předmětem státního či obchodního tajemství
Impakt faktor Impact factor: 2.853
Kód RIV RIV/00216224:14310/08:00026117
Organizační jednotka Přírodovědecká fakulta
UT WoS 000253135100006
Klíčová slova anglicky laser-induced breakdown spectroscopy; double-pulse; powdered samples; pellets; brick clay
Štítky brick clay, double-pulse, laser-induced breakdown spectroscopy, pellets, powdered samples
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnil: prof. RNDr. Viktor Kanický, DrSc., učo 408. Změněno: 18. 6. 2008 22:57.
Anotace
Single- and double-pulse laser-induced breakdown spectroscopy techniques applied to the analysis of pressed pellets of silicate raw materials were compared in terms of precision, sensitivity and limits of detection. Two Nd:YAG lasers (1064 and 532 mm) in an orthogonal configuration with a reheating arrangement have been employed. The main factors influencing system performance were optimized, i.e. laser pulse energies and interpulse separation. The behaviour of plasma temperature was studied over a period of time and calibration curves for Mg were constructed for both the single and double-pulse setup. When comparing the single- and double-pulse techniques, limits of detection of Si and Mg for the double-pulse technique were found to be 10 times lower.
Anotace česky
"Single- a double pulse" techniky spektroskopie laserem buzeného plazmatu byly srovnávány v aplikaci zaměřené na analýzu práškových vzorků silikátů pro keramický a cihlářský průmysl. Byly použity 2 Nd:YAG lasery (1064 nm a 532 nm) v ortogonální konfiguraci s uspořádáním "reheating". Byly optimalizovány podmínky (energie pulsů a zpoždění mezi pulsy). Vzorky byly lisovány do tablet. Byla studována teplota plazmatu, přesnost, správnost, citlivost a meze detekce vybraných prvků. Kalibrační závislosti pro hořčík byly srovnány pro režim "single pulse" a "double pulse".
Návaznosti
MSM0021622412, záměrNázev: Interakce mezi chemickými látkami, prostředím a biologickými systémy a jejich důsledky na globální, regionální a lokální úrovni (INCHEMBIOL) (Akronym: INCHEMBIOL)
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, Interakce mezi chemickými látkami, prostředím a biologickými systémy a jejich důsledky na globální , regionální a lokální úrovni
VytisknoutZobrazeno: 10. 5. 2024 12:41