RYVOLOVÁ, Markéta, Jan PREISLER, Pavel KRÁSENSKÝ, František FORET, Peter HAUSER, Brett PAULL and Miroslav MACKA. Combined 3-in-1 photometric, fluorimetric and contactless conductometric on-capillary detector for capillary separations: Applicability for simultaneous detection in CE. In CECE 2008 5th international interdisciplinary meeting on bioanalysis. 2008. ISBN 978-80-254-3194-8.
Other formats:   BibTeX LaTeX RIS
Basic information
Original name Combined 3-in-1 photometric, fluorimetric and contactless conductometric on-capillary detector for capillary separations: Applicability for simultaneous detection in CE
Name in Czech Kombinovaný 3v1 fotometrický, fluorimetrický a bezkontaktní vodivostní detektor pro kapilární separace: Aplikace pro simultání stanovení v CE
Authors RYVOLOVÁ, Markéta (203 Czech Republic), Jan PREISLER (203 Czech Republic, guarantor, belonging to the institution), Pavel KRÁSENSKÝ (203 Czech Republic), František FORET (203 Czech Republic), Peter HAUSER (756 Switzerland), Brett PAULL (372 Ireland) and Miroslav MACKA (203 Czech Republic).
Edition CECE 2008 5th international interdisciplinary meeting on bioanalysis, 2008.
Other information
Original language English
Type of outcome Conference abstract
Field of Study 10406 Analytical chemistry
Country of publisher Czech Republic
Confidentiality degree is not subject to a state or trade secret
RIV identification code RIV/00216224:14310/08:00058796
Organization unit Faculty of Science
ISBN 978-80-254-3194-8
Keywords in English capillary electrophoresis; simultaneous detection
Tags Capillary electrophoresis, simultaneous detection
Changed by Changed by: prof. Mgr. Jan Preisler, Ph.D., učo 45329. Changed: 9/4/2013 12:41.
Abstract
A new design of on-capillary detection combining 3 detection modes - photometric (PD), fluorimetric (FD) and contactless conductivity (C4D) - in one identical point of detection has been recently introduced, tested and characterised. This design allows a combined 3-in-1 detection in capillary separation techniques (CE, CEC, capillary- and nano-LC). A key advantage is the concurrent availability of the three independent on-column detection techniques in the same point, thus avoiding undesirable shifts in separation times caused by multiple parallel detectors. The per-definition concurrent availability of all the 3 detection modes (PD, FD, C4D) offers another unique advantage for the analysis of complex samples, where each of the single detection modes alone might yield an incomplete detection of the present analytes.
Abstract (in Czech)
Práce je zaměřena na demostraci využití kombinovaného detektoru(fotometrický, fluorimetrický a bezkontaktní vodivostní) pro CE. Byly ukázány příklady analýz z oblasti proteomiky nebo analýzy potravin
Links
LC06035, research and development projectName: Centrum biofyzikální chemie, bioelektrochemie a bioanalýzy. Nové nástroje pro genomiku, proteomiku a biomedicínu.
Investor: Ministry of Education, Youth and Sports of the CR, Centre of Biophysical Chemistry, Bioelectrochemistry and Bioanalysis. New Tools for Genomics, Proteomics and Biomedicine
MSM0021622415, plan (intention)Name: Molekulární podstata buněčných a tkáňových regulací
Investor: Ministry of Education, Youth and Sports of the CR, Molecular basis of cell and tissue regulations