NOVOTNÝ, Karel, Filip LUTZKÝ, Michaela GALIOVÁ, Jozef KAISER, Radomír MALINA, Viktor KANICKÝ a Vítězslav OTRUBA. Double pulse laser ablation and plasma: time resolved spectral measurements. CHEMICKÉ LISTY. Praha: Česká společnost chemická, 2008, roč. 102, č. 16, s. 1399-1402. ISSN 0009-2770. |
Další formáty:
BibTeX
LaTeX
RIS
@article{799522, author = {Novotný, Karel and Lutzký, Filip and Galiová, Michaela and Kaiser, Jozef and Malina, Radomír and Kanický, Viktor and Otruba, Vítězslav}, article_location = {Praha}, article_number = {16}, keywords = {laser induced breakdown spectroscopy; LIBS; double pulse LIBS; plasma characterization; time resolved measurement; ICCD; photomultiplier}, language = {eng}, issn = {0009-2770}, journal = {CHEMICKÉ LISTY}, title = {Double pulse laser ablation and plasma: time resolved spectral measurements}, volume = {102}, year = {2008} }
TY - JOUR ID - 799522 AU - Novotný, Karel - Lutzký, Filip - Galiová, Michaela - Kaiser, Jozef - Malina, Radomír - Kanický, Viktor - Otruba, Vítězslav PY - 2008 TI - Double pulse laser ablation and plasma: time resolved spectral measurements JF - CHEMICKÉ LISTY VL - 102 IS - 16 SP - 1399-1402 EP - 1399-1402 PB - Česká společnost chemická SN - 00092770 KW - laser induced breakdown spectroscopy KW - LIBS KW - double pulse LIBS KW - plasma characterization KW - time resolved measurement KW - ICCD KW - photomultiplier N2 - Most of the studies on double-pulse LIBS have been performed using an intensified CCD (ICCD) detection. Using ICCD, spectral information over wide range can be recorded on each laser pulse. Besides ICCD, also photomultipliers (PMT) can be used to monitor single emission lines. The output of the PMT is a current proportional to the intensity of the incident light. PMTs are not integrating devices as they provide a signal simultaneous in time with the incident light intensity. The combination of ICCD and PMT can be useful to determine both, the spectral and time resolved plasma emission. In this study, we present orthogonal re-heating double pulse experimental system equipped with both ICCD and PMT detection and preliminary measurements of temperatures of plasmas generated on an iron sample. ER -
NOVOTNÝ, Karel, Filip LUTZKÝ, Michaela GALIOVÁ, Jozef KAISER, Radomír MALINA, Viktor KANICKÝ a Vítězslav OTRUBA. Double pulse laser ablation and plasma: time resolved spectral measurements. \textit{CHEMICKÉ LISTY}. Praha: Česká společnost chemická, 2008, roč.~102, č.~16, s.~1399-1402. ISSN~0009-2770.
|