2009
A global benchmark study using affinity-based biosensors
RICH, Rebecca L., Giuseppe A. PAPALIA, Petr SKLÁDAL, [from all world] [109 OTHER AUTHORS], David G. MYSZKA et. al.Základní údaje
Originální název
A global benchmark study using affinity-based biosensors
Název česky
Globální srovnávací studie afinitních biosensor
Autoři
RICH, Rebecca L. (840 Spojené státy), Giuseppe A. PAPALIA (840 Spojené státy), Petr SKLÁDAL (203 Česká republika, garant), [from all world] [109 OTHER AUTHORS] (840 Spojené státy) a David G. MYSZKA (840 Spojené státy)
Vydání
Analytica Chimica Acta, Amsterdam, Elsevier Science Publishers, 2009, 0003-2670
Další údaje
Jazyk
angličtina
Typ výsledku
Článek v odborném periodiku
Obor
10600 1.6 Biological sciences
Stát vydavatele
Spojené státy
Utajení
není předmětem státního či obchodního tajemství
Odkazy
Impakt faktor
Impact factor: 3.757
Kód RIV
RIV/00216224:14310/09:00036491
Organizační jednotka
Přírodovědecká fakulta
UT WoS
000263789500009
Klíčová slova česky
Biosensor; Protilátka; Biacore
Klíčová slova anglicky
Biosensor; Antibody; Biacore
Příznaky
Mezinárodní význam, Recenzováno
Změněno: 28. 8. 2009 21:49, prof. RNDr. Petr Skládal, CSc.
V originále
To explore the variability in biosensor studies, 150 participants from 20 countries were given the same protein samples and asked to determine kinetic rate constants for the interaction. We chose a protein system that was amenable to analysis using different biosensor platforms as well as by users of different expertise levels. The two proteins (a 50-kDa Fab and a 60-kDa glutathione S-transferase [GST] antigen) form a relatively high-affinity complex, so participants needed to optimize several experimental parameters, including ligand immobilization and regeneration conditions as well as analyte concentrations and injection/dissociation times. Although most participants collected binding responses that could be fit to yield kinetic parameters, the quality of a few data sets could have been improved by optimizing the assay design. Once these outliers were removed, the average reported affinity across the remaining panel of participants was 620 pM with a standard deviation of 980 pM. These results demonstrate that when this biosensor assay was designed and executed appropriately, the reported rate constants were consistent, and independent of which protein was immobilized and which biosensor was used.
Česky
Srovnání výsledků studia stejného neznámého afinitního páru protilátka-antigen použitím různých typů afinitních biosensorů.
Návaznosti
LC06030, projekt VaV |
| ||
MSM0021622413, záměr |
|