2010
Calibration of the silicon rubber passive samplers: Relating sampling rate to hydrophobicity.
RUSINA, Tatsiana P., Foppe SMEDES, Martina KOBLIŽKOVÁ a Jana KLÁNOVÁZákladní údaje
Originální název
Calibration of the silicon rubber passive samplers: Relating sampling rate to hydrophobicity.
Název česky
Calibration of the silicon rubber passive samplers: Relating sampling rate to hydrophobicity.
Autoři
RUSINA, Tatsiana P. (112 Bělorusko), Foppe SMEDES (528 Nizozemské království), Martina KOBLIŽKOVÁ (203 Česká republika) a Jana KLÁNOVÁ (203 Česká republika, garant)
Vydání
Environmental Science & Technology, USA, The American Chemical Society, 2010, 0013-936X
Další údaje
Jazyk
angličtina
Typ výsledku
Článek v odborném periodiku
Obor
10511 Environmental sciences
Stát vydavatele
Spojené státy
Utajení
není předmětem státního či obchodního tajemství
Impakt faktor
Impact factor: 4.827
Kód RIV
RIV/00216224:14310/10:00043444
Organizační jednotka
Přírodovědecká fakulta
UT WoS
000273267000060
Klíčová slova česky
pasivní vzorkování hydrofobicita silikonová guma kalibrace
Klíčová slova anglicky
passive sampling hydrophobicity silicon rubber calibration
Změněno: 8. 3. 2010 22:30, prof. RNDr. Jana Klánová, Ph.D.
V originále
Using a new concept sampling rates (Rs) for silicone rubber (SR) passive samplers could be measured without the necessity to analyse aqueous phase concentrations. SR sheets of the large total surface area spiked with polycyclic aromatic hydrocarbons (PAHs) and polychlorinated biphenyls (PCBs) were applied as a dosing system. SR uptake sheets of much smaller surface were used to measure the uptake rate. For two experiments under largely different hydrodynamic conditions decreasing log linear relations of Rs with hydrophobicity and diffusion coefficients in water were found. The slopes were equal and the difference in exposure conditions was characterized by different intercepts. For extrapolation of Rs to higher hydrophobicity range an empirical model based on passive sampler-water partition coefficients (Kpw) was derived showing a good agreement with a theoretical model based on diffusion coefficients.
Česky
Using a new concept sampling rates (Rs) for silicone rubber (SR) passive samplers could be measured without the necessity to analyse aqueous phase concentrations. SR sheets of the large total surface area spiked with polycyclic aromatic hydrocarbons (PAHs) and polychlorinated biphenyls (PCBs) were applied as a dosing system. SR uptake sheets of much smaller surface were used to measure the uptake rate. For two experiments under largely different hydrodynamic conditions decreasing log linear relations of Rs with hydrophobicity and diffusion coefficients in water were found. The slopes were equal and the difference in exposure conditions was characterized by different intercepts. For extrapolation of Rs to higher hydrophobicity range an empirical model based on passive sampler-water partition coefficients (Kpw) was derived showing a good agreement with a theoretical model based on diffusion coefficients.
Návaznosti