BIDMANOVÁ, Šárka, Radka CHALOUPKOVÁ, Jiří DAMBORSKÝ a Zbyněk PROKOP. Development of an enzymatic fiber-optic biosensor for detection of halogenated hydrocarbons. Analytical and Bioanalytical Chemistry. Springer-Verlag, 2010, roč. 10, č. 1007, s. 1891-1898. ISSN 1618-2642.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Development of an enzymatic fiber-optic biosensor for detection of halogenated hydrocarbons.
Autoři BIDMANOVÁ, Šárka (203 Česká republika, domácí), Radka CHALOUPKOVÁ (203 Česká republika, domácí), Jiří DAMBORSKÝ (203 Česká republika, garant, domácí) a Zbyněk PROKOP (203 Česká republika, domácí).
Vydání Analytical and Bioanalytical Chemistry, Springer-Verlag, 2010, 1618-2642.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10600 1.6 Biological sciences
Stát vydavatele Německo
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 3.841
Kód RIV RIV/00216224:14310/10:00040599
Organizační jednotka Přírodovědecká fakulta
UT WoS 000283244500008
Klíčová slova česky Enzyme-based biosensor; Haloalkán dehalogenáza; Halogenované uhlovodíky; Optické biosensory; pH indikátory
Klíčová slova anglicky Enzyme-based biosensor; Haloalkane dehalogenase; Halogenated hydrocarbons; Optical biosensor; pH indicator
Změnil Změnil: prof. Mgr. Jiří Damborský, Dr., učo 1441. Změněno: 23. 3. 2012 10:58.
Anotace
An enzyme-based biosensor was developed by co-immobilization of purified enzyme haloalkane dehalogenase (EC 3.8.1.5) and a fluorescence pH indicator on the tip of an optical fiber. Haloalkane dehalogenase catalyzes hydrolytic dehalogenation of halogenated aliphatic hydrocarbons, which is accompanied by a pH change influencing the fluorescence of the indicator. The pH sensitivity of several fluorescent dyes was evaluated. The selected indicator 5(6)-carboxyfluorescein was conjugated with bovine serum albumin and its reaction was tested under different immobilization conditions. The biosensor was prepared by cross-linking of the conjugate in tandem with haloalkane dehalogenase using glutaraldehyde vapor. The biosensor, stored for 24 h in 50 mM phosphate buffer (pH 7.5) prior to measurement, was used after 15 min of equilibration, the halogenated compound was added, and the response was monitored for 30 min. Calibration of the biosensor with 1,2-dibromoethane and 3-chloro-2-(chloromethyl)- 1-propene showed an excellent linear dependence, with detection limits of 0.133 and 0.014 mM, respectively. This biosensor provides a new tool for continuous in situ monitoring of halogenated environmental pollutants.
Návaznosti
ED0001/01/01, projekt VaVNázev: CETOCOEN
IAA401630901, projekt VaVNázev: Evoluce substrátové specifity u enzymů aktivních s xenobiotickými látkami
Investor: Akademie věd ČR, Evoluce substrátové specifity u enzymů aktivních s xenobiotickými látkami
MSM0021622412, záměrNázev: Interakce mezi chemickými látkami, prostředím a biologickými systémy a jejich důsledky na globální, regionální a lokální úrovni (INCHEMBIOL) (Akronym: INCHEMBIOL)
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, Interakce mezi chemickými látkami, prostředím a biologickými systémy a jejich důsledky na globální , regionální a lokální úrovni
VytisknoutZobrazeno: 30. 5. 2024 22:26