Další formáty:
BibTeX
LaTeX
RIS
@inproceedings{916518, author = {Korytár, D. and Ferrari, C. and Mikulík, Petr and Dobročka, E. and Áč, V. and Konopka;, P. and Erko, A. and Abrosimov, N. and Zápražný, Z.}, address = {New York}, booktitle = {20th International Congress on X-Ray Optics and Microanalysis: AIP Conference Proceedings}, keywords = {X-ray monochromators and optics; X-ray beam conditioning; X-ray beam compression}, language = {eng}, location = {New York}, isbn = {978-0-7354-0764-0}, pages = {59-62}, publisher = {American Institute of Physics}, title = {1D X-ray Beam Compressing Monochromators}, url = {http://scitation.aip.org/getabs/servlet/GetabsServlet?prog=normal&id=APCPCS001221000001000059000001&idtype=cvips&gifs=yes&ref=no}, year = {2010} }
TY - JOUR ID - 916518 AU - Korytár, D. - Ferrari, C. - Mikulík, Petr - Dobročka, E. - Áč, V. - Konopka;, P. - Erko, A. - Abrosimov, N. - Zápražný, Z. PY - 2010 TI - 1D X-ray Beam Compressing Monochromators PB - American Institute of Physics CY - New York SN - 9780735407640 KW - X-ray monochromators and optics KW - X-ray beam conditioning KW - X-ray beam compression UR - http://scitation.aip.org/getabs/servlet/GetabsServlet?prog=normal&id=APCPCS001221000001000059000001&idtype=cvips&gifs=yes&ref=no N2 - A total beam compression of 5 and 10 corresponding to the asymmetry angles of 9 degrees and 12 degrees is achieved with V-5 and V-10 monochromators, respectively, in standard single crystal pure germanium (220) X-ray beam compressing (V-shaped) monochromators for CuK alpha(1) radiation. A higher 1D compression of X-ray beam is possible using larger angles of asymmetry, however it is achieved at the expense of the total intensity, which is decreased due to the refraction effect. To increase the monochromator intensity, several ways are considered both theoretically and experimentally. Linearly graded germanium rich GexSi(1-x) single crystal was used to prepare a V-21 single crystal monochromator with 15 degrees asymmetry angles (compression factor of 21). Its temperature gradient version is discussed for CuK alpha(1) radiation. X-ray diffraction measurements on the graded GeSi monochromator showed more than 3-times higher intensity at the output compared with that of a pure Ge monochromator. ER -
KORYTÁR, D., C. FERRARI, Petr MIKULÍK, E. DOBROČKA, V. ÁČ, P. KONOPKA;, A. ERKO, N. ABROSIMOV a Z. ZÁPRAŽNÝ. 1D X-ray Beam Compressing Monochromators. In \textit{20th International Congress on X-Ray Optics and Microanalysis: AIP Conference Proceedings}. New York: American Institute of Physics, 2010, s.~59-62. ISBN~978-0-7354-0764-0.
|