J 2010

Cementovaný dřík TEP Poldi-Čech po 25 letech

ROZKYDAL, Zbyněk a Pavel JANÍČEK

Základní údaje

Originální název

Cementovaný dřík TEP Poldi-Čech po 25 letech

Název česky

Cementovaný dřík Poldi- Čech po 25 letech

Název anglicky

Poldi-Cech Cemented Femoral Stem in Total Hip Arthroplasty after 25 Years

Autoři

ROZKYDAL, Zbyněk (203 Česká republika, garant, domácí) a Pavel JANÍČEK (203 Česká republika, domácí)

Vydání

Acta chirurgiae orthopaedicae et traumatologiae čechoslovaca, Praha, Galén, 2010, 0001-5415

Další údaje

Jazyk

čeština

Typ výsledku

Článek v odborném periodiku

Obor

30211 Orthopaedics

Stát vydavatele

Česká republika

Utajení

není předmětem státního či obchodního tajemství

Impakt faktor

Impact factor: 1.628 v roce 2009

Kód RIV

RIV/00216224:14110/10:00058944

Organizační jednotka

Lékařská fakulta

UT WoS

000281535100004

Klíčová slova česky

primární náhrada kyčle

Klíčová slova anglicky

primary total hip replacement; cemented stem.

Příznaky

Mezinárodní význam, Recenzováno
Změněno: 4. 10. 2012 12:02, Mgr. Michal Petr

Anotace

V originále

Totální náhrada kyčle vyráběná firmou Beznoska s ocelovým leštěným dříkem a s polyetylenovou jamkou je stále často používaným implantátem pro náhradu kyčelního kloubu u nás i v jiných zemích (7, 14, 15, 25). Její obliba u naší ortopedické veřejnosti je dána historicky i ekonomicky. Díky iniciativě prof. MUDr. O. Čecha a spolupracovníků byla v SONP Poldi Kladno, provoz Anticorro, vyvinuta a do sériové výroby dána endoprotéza TEP Poldi-Čech v roce 1972 (4). Vycházela z Múllerova konceptu cementovaného "banánového" dříku v kombinaci s polyetylenovou jamkou (17). Po úpravách se vyrábí tento dřík dodnes. Pracoviště autorů používá tuto endoprotézu již od začátku sedmdesátých let. Cílem našeho sdělení je prezentovat výsledky implantací s tímto dříkem po nejméně 25 letech.

Anglicky

The aim of the study was to evaluate the results of Poldi-Čech femoral stem implantation in primary total hip arthroplasty after 25 years. MATERIAL AND METHODS A group of 65 patients (90 hips) with Poldi-Čech total hip arthroplasty carried out between 1974 and 1984 was evaluated at the end of 2009. The mean follow-up of all patients was 28 years (25 to 35). There were seven men and 58 women. The mean age at the time of implantation was 43 years (26 to 60) and at the latest follow-up it was 72 years. In all patients the cemented UHMW PE acetabular component (RCH 1000) was used together with AKV Ultra 2 Poldi steel femoral stems (1st, 2nd and 3rd generations). The stem was a monoblock with a 32-mm head. The evaluation of the results was based on the Harris hip score and X ray with an A-P view of the pelvis and the affected hip. Statistical analysis was made using the life-table method. RESULTS At the latest follow up the mean Harris score was 69.7 points (40 to 88). There were 69 hips with an original Poldi-Čech femoral component still in situ, 64 of them were stable and five with radiological evidence of aseptic loosening. Five patients had undergone Girdlestone resection arthroplasty for septic loosening. Thirteen patients (16 hips) had femoral stem revision. The cumulative proportion of clinical survivorship of the Poldi-Čech femoral stem, with revision for any reason as the endpoint, .was 0.93 at 6 years, 0.84 at 12 years, and 0.77 at 18, 24 and 30 years after the index surgery. Radiograp-hic findings revealed 64 hips with stable stems, five hips with ;aseptic loosening (probable, 0 possible, 2, definite, 3). Sixteen hips were after revision surgery for aseptic loosening of the stem and five hips were after Girdlestone resection arthroplasty for septic failure. The cumulative proportion of radiological survivorship of the Poldi-Čech femoral stem with any reason as the endpoint was 0.92 at 6 years, 0.78 at 12 years, 0.72 at 18 years, 0.69 at 24 years and 0.69 at 30 years. DISCUSSION The Poldi-Čech stem with its anatomical shape and a highly polished surface meets the principles of successful composite beam stems. Its disadvantage is a valgus neck-shaft angle of 140deg. giving lower femoral offset and the risk of development of valgus deformity of the ipsilateral knee. In most cases osteolysis, radiolucent lines and bone rarefaction of the femur resulted from polyethylene wear of the acetabular component. CONCLUSIONS This study demonstrates a long-term survivorship of the Poldi-Čech femoral component in patients undergoing total hip arthroplasty 25 to 35 years ago.