NEČAS, Alois, Pavel PROKS, Lucie URBANOVÁ, Robert SRNEC, Ladislav STEHLÍK, Michal CRHA, Petr RAUŠER, Ladislav PLÁNKA, Evžen AMLER, Lucy VOJTOVÁ a Josef JANČÁŘ. Radiographic Assessment of Implant Failures of Titanium 3.5 LCP vs. 4.5 LCP Used for Flexible Bridging Osteosynthesis of Large Segmental Femoral Diaphyseal Defects in a Miniature Pig Model. Acta Veterinaria. Brno: VETERINARNI A FARMACEUTICKA UNIVERZITA B, 2010, roč. 79, č. 4, s. 599-606, 7 s. ISSN 0001-7213. |
Další formáty:
BibTeX
LaTeX
RIS
@article{930480, author = {Nečas, Alois and Proks, Pavel and Urbanová, Lucie and Srnec, Robert and Stehlík, Ladislav and Crha, Michal and Raušer, Petr and Plánka, Ladislav and Amler, Evžen and Vojtová, Lucy and Jančář, Josef}, article_location = {Brno}, article_number = {4}, keywords = {Fracture fixation; bone healing; comminuted fracture; nonunion; ostectomy; buttress plate}, language = {eng}, issn = {0001-7213}, journal = {Acta Veterinaria}, title = {Radiographic Assessment of Implant Failures of Titanium 3.5 LCP vs. 4.5 LCP Used for Flexible Bridging Osteosynthesis of Large Segmental Femoral Diaphyseal Defects in a Miniature Pig Model}, volume = {79}, year = {2010} }
TY - JOUR ID - 930480 AU - Nečas, Alois - Proks, Pavel - Urbanová, Lucie - Srnec, Robert - Stehlík, Ladislav - Crha, Michal - Raušer, Petr - Plánka, Ladislav - Amler, Evžen - Vojtová, Lucy - Jančář, Josef PY - 2010 TI - Radiographic Assessment of Implant Failures of Titanium 3.5 LCP vs. 4.5 LCP Used for Flexible Bridging Osteosynthesis of Large Segmental Femoral Diaphyseal Defects in a Miniature Pig Model JF - Acta Veterinaria VL - 79 IS - 4 SP - 599-606 EP - 599-606 PB - VETERINARNI A FARMACEUTICKA UNIVERZITA B SN - 00017213 KW - Fracture fixation KW - bone healing KW - comminuted fracture KW - nonunion KW - ostectomy KW - buttress plate N2 - Compared to the six-hole 3.5 mm LCP, the five-hole titanium 4.5 mm LCP is more suitable implant for flexible bridging osteosynthesis of a critically sized segmental defect of femoral diaphysis in the miniature pig. The results of this study will allow reducing implant failures in time-and cost-demanding transplantation experiments focused on bone healing. Compared to the six-hole 3.5 mm LCP, the five-hole titanium 4.5 mm LCP is more suitable implant for flexible bridging osteosynthesis of a critically sized segmental defect of femoral diaphysis in the miniature pig. The results of this study will allow reducing implant failures in time-and cost-demanding transplantation experiments focused on bone healing. ER -
NEČAS, Alois, Pavel PROKS, Lucie URBANOVÁ, Robert SRNEC, Ladislav STEHLÍK, Michal CRHA, Petr RAUŠER, Ladislav PLÁNKA, Evžen AMLER, Lucy VOJTOVÁ a Josef JANČÁŘ. Radiographic Assessment of Implant Failures of Titanium 3.5 LCP vs. 4.5 LCP Used for Flexible Bridging Osteosynthesis of Large Segmental Femoral Diaphyseal Defects in a Miniature Pig Model. \textit{Acta Veterinaria}. Brno: VETERINARNI A FARMACEUTICKA UNIVERZITA B, 2010, roč.~79, č.~4, s.~599-606, 7 s. ISSN~0001-7213.
|